![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2207283.1 : Oracle ZFS Storage Appliance: How to set Auto-Connect option in ILOM when a reboot is triggered by a power failure
In this Document
Created from <SR 3-13435496591> Applies to:Oracle ZFS Storage ZS3-2 - Version All Versions and laterOracle ZFS Storage ZS3-4 - Version All Versions and later PDIT Single Rack ZFS Storage ZS4-4 - Version All Versions and later Oracle ZFS Storage ZS4-4 - Version All Versions and later Oracle ZFS Storage Appliance Racked System ZS4-4 - Version All Versions and later 7000 Appliance OS (Fishworks) GoalQuestion: How to set auto-connect in ILOM when the storage reboots due to a power trip? SolutionSetting the auto-connect option in ILOM (restore Host Power State): ****************************************************
Set Host to Last Power State on Boot (HOST_LAST_POWER_STATE=) Disabled (default) |Enabled ****************************************************
Enable this policy to set the host server power state to the last known state at boot.
Note - Enabling this policy automatically disables the policy for “Auto power-on host policy” if enabled.
CLI Syntax for Set Host to Last Power State on Boot: set /SP/policy HOST_LAST_POWER_STATE= enabled|disabled
Related information available in the Oracle Integrated Lights Out Manager (ILOM) 3.1 Configuration and Maintenance Guide: http://docs.oracle.com/cd/E24707_01/pdf/E24522.pdf (Page 172)
Attachments This solution has no attachment |
||||||||||||||
|