Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2202118.1
Update Date:2017-11-12
Keywords:

Solution Type  Technical Instruction Sure

Solution  2202118.1 :   How to Enable SIGTRAN RID Enhancement in MAP xDR Builder?  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Goal
Solution
References


Created from <SR 3-12859756331>

Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 10.2.0 and later
Information in this document applies to any platform.

Goal

Enable SIGTRAN RID enhancement to have a part of SCCP address in Matching ID (RID) instead of Point Code (PC). 

Solution

Configuration must be set as follow:

  • At SS7 Transport layer, RID must be set to "International RID".
  • At MAP2 TDR, Reconstitution mode must be set to "Transaction Id and Global Title" and "Length of SCCP address in GT mode" to "One thirds".
  • Way Management must be enabled and configured on PDU Dataflow at PMF level.
Latest PIC 10.2 patches must be installed. More information in 2118743.1

 

References

<BUG:23598548> - SIGTRAN RID ENHANCEMENT
<NOTE:2118743.1> - Which Performance Intelligence Center (PIC) 10.2.0 Patches to Update and How to Install Them ?

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.