![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2201801.1 : Question On The Loadsharing With The MAPset Table For Different SSN Values
In this Document
Created from <SR 3-13441599618> Applies to:Oracle Communications EAGLE (Software) - Version EAGLE 43.x and laterInformation in this document applies to any platform. Goalquestion : When the MSU come to (PC s-2856, SSN=7) , will the MSU be loadshared to (PC s-2856, SSN=8) or to (PC s-2856, SSN=146) ? MAPSET ID=8
PCN Mate PCN SSN RC MULT SRM MRC GRP NAME SSO s-02856 7 10 COM NO *Y -------- OFF s-02856 8 10 COM NO *Y -------- OFF s-02856 146 10 COM NO *Y -------- OFF s-02857 129 20 COM NO *Y -------- OFF SolutionAfter GTT translation, if the translated PC/SSN is (s-2856 / 7), then Eagle will check the Mapset table. This is a very particular case where different subsystems will process MSU normally addressed to the SSN=7. MAPSET ID=10
PCN Mate PCN SSN RC MULT SRM MRC GRP NAME SSO s-01060 6 10 DOM NO NO -------- OFF s-01087 6 20 DOM NO NO -------- OFF MAPSET ID=11 PCN Mate PCN SSN RC MULT SRM MRC GRP NAME SSO s-01060 10 10 DOM NO NO -------- OFF s-01087 10 20 DOM NO NO -------- OFF
Attachments This solution has no attachment |
||||||||||||||
|