Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2196548.1
Update Date:2018-05-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  2196548.1 :   Oracle ZFS Storage Appliance: How to configure dedicated management interfaces  


Related Items
  • Sun ZFS Storage 7320
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Oracle ZFS Storage ZS5-4
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS5-2
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Sun ZFS Storage 7120
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: ZS
  •  




In this Document
Goal
Solution
References


Created from <SR 3-13500204471>

Applies to:

Oracle ZFS Storage ZS3-2 - Version All Versions to All Versions [Release All Releases]
Oracle ZFS Storage ZS4-4 - Version All Versions to All Versions [Release All Releases]
Sun ZFS Storage 7420 - Version All Versions to All Versions [Release All Releases]
Sun ZFS Storage 7320 - Version All Versions to All Versions [Release All Releases]
Oracle ZFS Storage ZS3-4 - Version All Versions to All Versions [Release All Releases]
7000 Appliance OS (Fishworks)

Goal

 Configure network interfaces as a dedicated connections to each node of a ZFS Storage Appliance cluster system.

 

Solution

Symptoms

When a ZFS Storage Appliance is in the OWNER / STRIPPED (active/passive) state, if no dedicated management interface has been defined, no network access to the STRIPPED node will be available.

 

Changes

On initial configuration or reconfiguration of a ZFS Storage Appliance Cluster no management interface is defined to access each node.

 

Cause

By default, network interfaces configured on a ZFS Storage Appliance cluster are cluster resources (SINGLETON).

In an optimal state, cluster resources will be on their assigned head; however, following a takeover event, all cluster resources will be on the OWNER head.

This leaves the STRIPPED head with no network interfaces and only accessible via the ILOM.

In order for a STRIPPED node to retain a network interface it must be configured as PRIVATE, represented in the Browser User Interface (BUI) as a locked padlock.

 

Cluster States

  • AKCS_CLUSTERED : Both nodes are running in normal condition sharing resources.
  • AKCS_OWNER : One node in the cluster owns all of the shared cluster resources
  • AKCS_STRIPPED : One node has joined the cluster but does not own any cluster resources (the node is waiting for the administrator to perform a failback operation)

 

 

Resolution

For the process of configuring a management interface reference:

 Oracle® ZFS Storage Appliance Administration Guide, Configuring Management Interfaces

 

 

 

Check for relevancy - 10-May-2018