Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2193916.1
Update Date:2016-10-21
Keywords:

Solution Type  Technical Instruction Sure

Solution  2193916.1 :   Performance Intelligence Center (PIC) - How to Enhance Alarm Description and Classification in Alarm Application  


Related Items
  • Oracle Communications Performance Intelligence Center (PIC) Software
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
  •  




In this Document
Goal
Solution
References


Applies to:

Oracle Communications Performance Intelligence Center (PIC) Software - Version 10.1.0 to 10.2.0 [Release 10.0]
Information in this document applies to any platform.

Goal

 How to enhance alarm description and classification in PIC Alarms applications after a fresh installation to get more information about the alarms and the way to fix them.

Solution

 Due to a bug the Alarms enhancement script is not applied after a fresh Install in PIC10.1.5, PIC10.1.5.1 and PIC10.2. It is recommended to apply it to get better information about the alarms.

  1. Open a terminal window and log in as root user on Management Server(one box)
  2. Change user to Oracle and execute given command with Management Server database sql user and password
[root]# su – oracle
[oracle]$ sqlplus user/password @/usr/TKLC/nsp/nsp-package/framework/core/dist/coreDB/sql/CORdb_AlarmEnhancement_data.sql

To get latest procedure, check installation documentation of PIC (link). 

References

<BUG:21565478> - ALARM ENHANCEMENT MISSING AFTER FRESH INSTALLATION