Solution Type Technical Instruction Sure Solution 2191813.1 : PM&C(PMAC) OpenHPI Daemon Stuck In IN_PROGRESS (Error Discovering - Retrying)
In this Document
Created from <SR 3-13192778721> Applies to:Oracle Communications Diameter Signaling Router (DSR) - Version DSR 6.0 and laterInformation in this document applies to any platform. GoalOpenHPI Daemon process stuck in IN_PROGRESS (Error discovering - retrying) while try to add or rediscover the enclosure Discovery on an enclosure is done in two phases. PMAC discovers the hardware and then the software on each blade. Here PMAC is not getting through the initial hardware discovery. SolutionCheck the "openhpid" process status by following command on PMAC: sudo ps -ef|grep openhpid
Restart the process to start over the rediscovery of the enclosure. kill -9 <Process ID>
In some cased multiple restart attempts of the "openhpid" process may be needed. The issue may re-appear after the PM&C server restart.
The below commands are to check the output of the openhpi process, as discovery takes place.
Attachments This solution has no attachment |
||||||||||||||
|