Goal
Solution


Created from <SR 3-13361650891>

Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.0.1 and later
Information in this document applies to any platform.

Goal

To clear Minor Alarm 31131 DB Ousted Throttle Behind on DSR MP.

Solution

Alarm eventually cleared on its own after a few days.

If it needs to be cleared in a more urgent time frame then the following can be attempted in a maintenance window:

The steps here are to address the minor alarm (Minor Alarm 31131 DB Ousted Throttle Behind) on MP in DSR site

  1. Verify issue is present (output is expected):
    sudo procshm -o
  2. Stop and restart the DSR process from the GUI (Main Menu: Status & Manage -> Server)
  3. Verify issue has disappeared:
    sudo procshm -o (should show no output)
  4. Verify DSR restarts OK based on most recent spawnTime in output:
    sudo pl
  5. Verify in Active Alarms that the alarm is cleared
This should be done in a Maintenance Window as it will affect all connections on MP1.


 