Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2187079.1
Update Date:2016-10-04
Keywords:

Solution Type  Technical Instruction Sure

Solution  2187079.1 :   19 Digit Range To Be Defined As Per DOT  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution


Created from <SR 3-13358523291>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 46.1 and later
Information in this document applies to any platform.

Goal

We are not able to define 19 digits range in GTTSET
 

Solution


The error message is normal as you have the feature VGTT on.
You don't have to enter the ndgt=19, as beacuse of the VGTT feature Eagle is considering that the digits length of the gta may vary.
Here is an except from the Eagle GTT feature manual :

"If the GTT set has less than the maximum number of different length global title addresses assigned to it, and another global title address is specified for the GTT set,
the length of the global title address can be from one to 21 digits and does not have to match the length of the other global title addresses assigned to the translation type or the GTT set"