![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 2185194.1 : How to Identify FC HBA or PCI Card on ILOM Snapshot from T3/T4/T5 Servers Platform
In this Document
Created from <SR 3-13324978664> Applies to:SPARC T4-1 - Version All Versions and laterInformation in this document applies to any platform. GoalIn the absence of a explorer, it may be useful to Identify FC HBA or PCI Card model on ILOM Snapshot from T3/T4/T5 Servers Platform SolutionAll the components of a server should be on the file @usr@local@bin@collect_properties.out , available on this path on the ILOM snapshot server01-lom_XXXXXDYE14_2016-09-15T08-10-52/ilom/@usr@local@bin@collect_properties.out Example: /System/PCI_Devices/Add-on/Device_4
Properties: part_number = SG-XPCIE2FC-QF8-Z description = Sun StorageTek Dual 8 Gb Fibre Channel PCIe HBA location = PCIE4 (PCIe Slot 4) pci_vendor_id = 0x1077 pci_device_id = 0x2532 pci_subvendor_id = 0x1077 pci_subdevice_id = 0x0171
The pci_subdevice_id correspond with the subsystem-id or "Subsys Device ID" or SSID
Notice. When the properties part_number and description are Not Recognized Example: /System/PCI_Devices/Add-on/Device_0
Properties: part_number = Not Recognized description = Not Recognized location = PCIE0 (PCIe Slot 0) pci_vendor_id = 0x1077 pci_device_id = 0x2532 pci_subvendor_id = 0x1077 pci_subdevice_id = 0x015d <<<----
That value 0x15d is from a non-Oracle card, on this case this is a native Qlogic FC HBA, On a explorer we can confirm, that subsystem-id from prtpicl is pci_subdevice_id on ILOM, subsystem-id 0x15d subsystem-id 0x15d
References<NOTE:1282491.1> - Solaris: How to Identify Oracle[TM] Branded Fibre Channel (FC) HBA, CNA/FCoE and Universal 16GB HBA Cards and Their Slot LocationsAttachments This solution has no attachment |
||||||||||||||||
|