Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2182984.1
Update Date:2017-10-03
Keywords:

Solution Type  Technical Instruction Sure

Solution  2182984.1 :   SL3000: How to Diagnose CAP Issues  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  




In this Document
Goal
Solution


Created from <SR 3-13315561332>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Goal

Steps that can be used to diagnose CAP issues
 

Solution

Recommendations:

  • In SLC check the Cap status; Expected State; Reserved True and Reserver Scsi0.
  • If necessary toggle the Cap state at the Host.
  • Test the Cap with host operations.
  • If problems continue go to SLC-Tools-Reports-Status Summary-Cap Table, save the report and upload for review.
  • Send in another log snapshot for follow up.