Solution Type Technical Instruction Sure Solution 2179844.1 : A Critical Alarm ''Notification Table Full'' Is Raised And Auto Cleared During OCUDR Migration
In this Document
Created from <SR 3-13286619041> Applies to:Oracle Communications User Data Repository - Version UDR 10.0 and laterInformation in this document applies to any platform. GoalWhy are we seeing a critical alarm is raised and auto clear few seconds after regarding table utilization. SolutionThese types of alarms are the result of the transition period when the DR site MPs did not have active DIAM connections to the MPEs of the PCRF. Possible causes : 1.The rate at which notifications are being produced exceeds the rate at which they can be delivered. 2. Notifications cannot be delivered to AS(s) because they are unavailable, and the notifications are being buffered for delivery at a later time.
The alarm severity depends upon the amount of the Notification Table being used: -Minor when utilization exceeds 60%. -Major when utilization exceeds 80%. -Critical when utilization exceeds 95%. Please see KM Document: 2180177.1 for related information References<NOTE:2180177.1> - Major Alarm ''AS Unvailable'' Is Raised For All MPE And Then Auto ClearsAttachments This solution has no attachment |
||||||||||||||||
|