Solution Type  Technical Instruction Sure

Solution  2179836.1 :   MAP Screening : UIM 1250 - SCCP rcvd undefined MAP Op-Code  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution


Created from <SR 3-13109628861>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Information in this document applies to any platform.

Goal

Eagle is issuing the UIM 1250 "SCCP rcvd undefined Map Op-Code”.
Question : why this packet is received without opcode ?

9496.1250 CARD 1207 INFO SCCP rcvd undefined Map Op-Code
OPC= s-01020 DPC= s-01054
CDPA: NI=0 RI=0 GTI=04 SSNI=1 PCI=0
TT=000 NP=01 NAI=004 ADDR=917021075042
PC=-------------- SSN=147
CGPA: NI=0 RI=0 GTI=04 SSNI=1 PCI=0
TT=000 NP=01 NAI=004 ADDR=917021075063
PC=-------------- SSN=006
Op-Code=--- Forbidden Param=n/a Action=pass

 

Solution

Eagle is issuing this UIM because it is receiving messages with an undefined OpCode.

The undefined OpCode received by the Eagle is the value 36.
See the below message from ENT-TRACE at the REP=48 :

  eaglestp16-08-26 00:25:29 IST EAGLE5 46.0.0-65.26.0
  MSU TRACE H'0061: Card=1217
  Trace ID 1 Condition: (brief=Y, MSU size=102)
  REPEAT= 48
  CARD= VSCCP
  GT= 21075049
  SI= 3
  MODE= debug
  
  Info: Ret Error Component - no OPCODE. Code=36


 

  eaglestp 16-08-26 00:25:30 IST EAGLE5 46.0.0-65.26.0
  MSU TRACE H'0061: Card=1217
  Trace ID 1 Condition: (brief=Y, MSU size=102)
  REPEAT= 48
  CARD= VSCCP
  GT= 21075049
  SI= 3
  MODE= debug
  
  Info: GMS: ITU TCAP validation PASSED: NO OPCODE in the Package 100

 

  eaglestp 16-08-26 00:25:30 IST EAGLE5 46.0.0-65.26.0
  MSU TRACE H'0061: Card=1217
  Trace ID 1 Condition: (brief=Y, MSU size=102)
  REPEAT= 48
  CARD= VSCCP
  GT= 21075049
  SI= 3
  MODE= debug
  
  Info: GMS: MSU has no OPCODE and * not provisioned

The value 36 is not a known Opcode.
The "*" is not provisioned in your MAP screening configuration for Opcode. if you configure a "*" value then Eagle will process all received undefined values according to the rule for "*" and you will not't get this UIM.
The unknown OpCode=36 comes from OPC=s-1020
 