Solution Type  Technical Instruction Sure

Solution  2179735.1 :   Disk Firmware State: Unconfigured(good), Spun Down  


Related Items
  • Exadata X3-8 Hardware
  •  
Related Categories
  • PLA-Support>Eng Systems>Exadata/ODA/SSC>Oracle Exadata>DB: Exadata_EST
  •  




Created from <SR 3-13158282721>

Applies to:

Exadata X3-8 Hardware - Version All Versions and later
Information in this document applies to any platform.

Goal

The disk firmware state shows unconfigured(good) and spun down.

How to correct?

[root@myexadm02 ~]# /opt/MegaRAID/MegaCli/MegaCli64 -PDList -aALL | grep state
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
Firmware state: Unconfigured(good), Spun down
Firmware state: Online, Spun Up
Firmware state: Online, Spun Up
[root@myexadm02 ~]#
 

Solution

Run the command and check if it changes the firmware status :-

/opt/MegaRAID/CLI/MegaCli -CfgLdAdd -R0[16:5] WB NORA Direct NoCachedBadBBU -strpsz1024 -a0
 