![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 2179042.1 : DSR Event 22008 - "Orphan Answer Response" Received Recovery Information In "DSR Alarms and KPIs Reference" Revision 01 (DSR 7.0.1)
In this Document
Created from <SR 3-13192794681> Applies to:Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.0.1 to DSR 7.4.0 [Release DSR 7.0]Information in this document applies to any platform. GoalThe Recovery section for the Event 22008. The Recovery section given in the customer documentation require correction. SolutionThe Recovery section in the customer documentation (mentioned below) require correction. Alarms and KPIs Reference E57505 Revision 01 ( DSR 7.0.1 ) As per the document the recovery of the event 22008 is as below: If this event is occurring frequently, the transaction timers may be set too low. The timer values can be viewed and/or modified using the Diameter > Configuration > System Options page. There is no timer related configuration at above option given in Recovery. The correct location to view the timer values is : "Diameter-->Configuration-->Pending Answer Timer." Examine the Pending Answer Timers assignment via the Diameter > Configuration > Application Ids and Diameter > Configuration >Peer Nodes.
References<BUG:24577426> - 22008 - ORPHAN ANSWER RESPONSE RECEIVEDAttachments This solution has no attachment |
||||||||||||||||
|