Solution  2178759.1 :   Some Private Cloud Appliance (PCA) x6-2 compute nodes have incorrectly programmed FRUID data  


Related Items
  • Private Cloud Appliance
  •  
  • Private Cloud Appliance X6-2 Server Upgrade
  •  
  • Private Cloud Appliance X5-2 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>x86>Engineered Systems HW>SN-x86: OVCA
  •  




In this Document
Goal
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Internal Process

Applies to:

Private Cloud Appliance X6-2 Server Upgrade - Version All Versions and later
Private Cloud Appliance - Version 2.2.1 and later
Private Cloud Appliance X5-2 Hardware - Version All Versions and later
Information in this document applies to any platform.

Goal

A few PCA x6-2 nodes had incorrectly FRUID data programmed at the factory.  This doc contains the field actions for resolution.

Solution

Some X6-2 PCA compute nodes were shipped with wrong FRUID programmed in the ILOM.
This will cause provisioning to fail.

Serial number of effected nodes.

1635NM10AR
1635NM10AP
1634NM1071
1634NM1070
1632NM11K2
1632NM11K3
1632NM11K1
1632NM11K0
1632NM11JY
1632NM11JW
1632NM11JX
1632NM11JV
1632NM100F
1632NM100J
1632NM100H
1632NM100E
1632NM100L
1632NM100G
1632NM100K
1632NM100D
1631NM10KN
1631NM10KW
1631NM10KV
1631NM10KU
1631NM10KT
1631NM10KR
1631NM10KP

The resolution is to reprogram the three containers with the correct PCA specific data.
This reprogramming is done by an FE via escalation mode.
If needed, see How to access service mode and escalation mode on ILOM 3.x and later platforms (Doc ID 1019946.1)
An SR into the X86 HW team may be required to get the required escalation mode password.

Once in escalation mode, issue these three commands.
Note:  Do not reboot the SP until the final one has been reprogrammed.

[(flash)root@ILOM-ovcacn13r1:~]# setsvcid -n "OVCA X6-2" PRIMARY
Reading fruid:///SYS/DBP...
.
Top Level Product Name: OVCA X6-2
Top Level PPN: OVCA X6-2
Top Level PSN: AK00298625
Chassis Name: ORACLE SERVER X6-2
Chassis PN: 7320022
Chassis SN: 1622NM108T
Writing fruid:///SYS/DBP...
You will need to reboot the SP for these changes to take full effect.

[(flash)root@ILOM-ovcacn13r1:~]# setsvcid -n "OVCA X6-2" BACKUP1
Reading fruid:///SYS/MB...
.
Top Level Product Name: OVCA X6-2
Top Level PPN: OVCA X6-2
Top Level PSN: AK00298625
Chassis Name: ORACLE SERVER X6-2
Chassis PN: 7320022
Chassis SN: 1622NM108T
Writing fruid:///SYS/MB...
You will need to reboot the SP for these changes to take full effect.

[(flash)root@ILOM-ovcacn13r1:~]# setsvcid -n "OVCA X6-2" BACKUP2
Reading fruid:///SYS/PS0...
.
Top Level Product Name: OVCA X6-2
Top Level PPN: OVCA X6-2
Top Level PSN: AK00298625
Chassis Name: ORACLE SERVER X6-2
Chassis PN: 7320022
Chassis SN: 1622NM108T
Writing fruid:///SYS/PS0...
You will need to reboot the SP for these changes to take full effect.

[(flash)root@ILOM-ovcacn13r1:~]# reboot
/sbin/reboot

 After the SP has reboot, enter escalation mode again and confirm the fields are still correctly programmed.

[(flash)root@ILOM-ovcacn13r1:~]# showsvcid
Chassis Manufacturer: Oracle Corporation
Chassis Name: ORACLE SERVER X6-2
Chassis Part Number: 7320022
Chassis Serial Number: 1622NM108T

Top Level Product Manufacturer: Oracle Corporation
Top Level Product Name: OVCA X6-2
Top Level PPN: OVCA X6-2
Top Level PSN: AK00298625
[(flash)root@ILOM-ovcacn13r1:~]#

 See References Section below for additional information.

References

<NOTE:2174850.1> - Oracle Server X6-2 shown as state=ignore_non_ilom after update PCA Rack to 2.2.1