Solution Type Technical Instruction Sure Solution 2174934.1 : EAGLE :: What Should Be IPSM Card Port Configuration?
In this Document
Created from <SR 3-13172784311> Applies to:Oracle Communications EAGLE (Hardware) - Version EAGLE 3x.x and laterTekelec GoalCurrently the IPSM ports are configured as 100 Full Duplex Non-auto-negotiate but the connected switch ports are set to Half-duplex, 100Mb/s, link type is auto, media type is 10/100/1000-TX I am seeing collisions over this interface. STPCLLI 16-08-12 11:01:41 BST EAGLE5 45.0.1-64.70.35
LOC PORT IPADDR SUBMASK DUPLEX SPEED MACTYPE AUTO MCAST 1101 A 192.168.186.186 255.255.255.240 FULL 100 DIX NO NO 1101 B --------------- --------------- HALF 10 DIX NO NO IP-LNK table is (18 of 512) 4% full. ; Command Executed > rtrv-ip-lnk:loc=1103 STPCLLI 16-08-12 11:01:54 BST EAGLE5 45.0.1-64.70.35 rtrv-ip-lnk:loc=1103 Command entered at terminal #29. ; Command Accepted - Processing STPCLLI 16-08-12 11:01:54 BST EAGLE5 45.0.1-64.70.35 LOC PORT IPADDR SUBMASK DUPLEX SPEED MACTYPE AUTO MCAST 1103 A 192.168.186.187 255.255.255.240 FULL 100 DIX NO NO 1103 B --------------- --------------- HALF 10 DIX NO NO
SolutionThe settings should match on both sides i.e. card and the switch. Attachments This solution has no attachment |
||||||||||||||
|