Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2168081.1
Update Date:2016-08-08
Keywords:

Solution Type  Technical Instruction Sure

Solution  2168081.1 :   E5-MS Not All The Reporting Studio Information Is Coming From The STP's  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
  •  


Sometimes the STP's are getting properly configured and they stop collecting data.This causes to the customer not able to receive measurement reports.

In this Document
Goal
Solution


Created from <SR 3-12810172951>

Applies to:

Oracle Communications EAGLE (Software) - Version E5-MS 45.0 and later
Information in this document applies to any platform.
Title:
Check the measurements are being received in the E5-MS

Product:
E5-MS starting from version 45

Problem:
The measurement information isn't being received in the E5-MS.

Description:

The STP's could stop collecting data, hence not sending measurement files to the E5-MS.

Goal

Verify the STP is receiving the measurement information. If not being received fix the issue.

Solution

You need to check a couple of commands in the STP, and a folder in the E5-MS to verify the information is being received.}

 

  • rept-stat-meas

stp3 16-04-18 09:43:06 IST EAGLE5 45.0.0-64.70.31
rept-stat-meas
Command entered at terminal #17.
;

Command Accepted - Processing
stp3 16-04-18 09:43:06 IST EAGLE5 45.0.0-64.70.31
PST SST AST
MEAS SS IS-NR Active -----
ALARM STATUS = No Alarms

CARD VERSION TYPE PST SST AST
1113 134-070-031 E5MCAP IS-NR Standby -----
IP Link A OOS-MT Unavail -----
1115 P 134-070-031 E5MCAP IS-NR Active -----
IP Link A IS-NR Active -----

CARD 1113 ALARM STATUS = No Alarms
CARD 1115 ALARM STATUS = No Alarms

This will show you if the active MASP is connected to the network, if it shows the ip link unavailable, the measurement can't be send.

  • rtrv-measopts

Collect :on

this will show the options of the command, but the one you need to verify is the collect, it has to be turned on.
if it is off, you can change it to chg-meas:collect=on.

  • On the side of the E5-MS you need to check the following directories.

/root/E5-MS/measurement/csvinput

/var/E5-MS/measurement/csvoutput

In the csvoutput the measurement will be stored. With this information you can verify the measurements.
 