![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2162033.1 : How to Replace an Exadata X4-8, X5-8, X6-8 Compute Node Fan Module
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Exadata X4-8 Hardware - Version All Versions to All Versions [Release All Releases]Exadata X5-8 Hardware - Version All Versions to All Versions [Release All Releases] Exadata X6-8 Hardware - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalHow to Replace an Exadata X4-8, X5-8, X6-8 Compute Node Fan Module. SolutionDISPATCH INSTRUCTIONS PROBLEM OVERVIEW: An Exadata X4-8/X5-8/X6-8 Compute Node Fan module needs replacement WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : The Fan Module can be replaced online Oracle Server X5-8 Service Manual ==========================================================================
Caution - Potential for system over-temperature and component damage. Do not attempt to operate the system with insufficient cooling. Maintain the integrity of a properly functioning cooling system by immediately replacing nonworking components and ensuring unobstructed airflow. ==========================================================================
==========================================================================
Caution ‐ Electrical hazard. During a hot-service procedure, voltage is present. Do not reach into the vacant fan module slot with your hand or any object. Do not touch the exposed CMOD fan module power connector. ========================================================================== ==========================================================================
Caution - Server over-temperature condition. When a Fan module is removed, the airflow vanes in the Subassembly module automatically close to maintain the integrity of the server cooling system. Do not defeat the purpose of the airflow vanes. ==========================================================================
3.Verify that the green Fan OK indicator on the fan module lights and is on steady. -> show /System/Cooling/Fans/Fan_0
/System/Cooling/Fans/Fan_0 Targets: Properties: health = OK health_details = - part_number = Not Supported serial_number = Not Supported location = FM0 (Fan Module 0) fan_percentage = 37 %
-> start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y faultmgmtsp> fmadm faulty No faults found
fmadm faulty -a
STATE RESOURCE / UUID -------- ---------------------------------------------------------------------- Attachments This solution has no attachment |
||||||||||||||
|