![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 2160485.1 : How to Replace Sun Enterprise T5440 Flex Cable Assembly (Cable Kit)
Oracle Confidential PARTNER - Available to partners (SUN). Reason: FRU part Applies to:Sun SPARC Enterprise T5440 Server - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. GoalHow to replace a Sun Enterprise T5440 Flex Cable Assembly (Cable Kit) ***************************************************************************************** SolutionDISPATCH INSTRUCTIONS Sun Enterprise T5440 Product training and/or sufficient field support experience. The host should be shut down & power removed. Remove the Flex Cable Assembly Before you begin, complete these tasks: Read the section, Safety Information. Power off the server, using one of the methods described in the Service Manual section: Powering Off the System. Extend the Server to the Maintenance Position Perform Electrostatic Discharge – Antistatic Prevention Measures Remove the Top Cover Do the following steps: 1) Unplug the power cords. 3) Unplug the flex cable-to-power supply backplane connection. Loosen the captive No.2 Phillips screw and lift the retainer up and out of the chassis.
Install the Flex Cable Assembly 1) Ensure the power cables are unplugged. Place the retainer into position and tighten the captive No. 2 Phillips screw.
https://support.oracle.com/handbook_partner/Systems/SE_T5440/components.html
Attachments This solution has no attachment |
||||||||||||
|