![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2160400.1 : How to Correlate More Than Two MAP Transactions in Same xDR on Performance Intelligence Center?
In this Document
Created from <SR 3-12996255941> Applies to:Oracle Communications Performance Intelligence Center (PIC) Software - Version 7.1 and laterInformation in this document applies to any platform. GoalHow to correlate multiple begin (more than two) in same xDR? SolutionIf there same MAP transaction is captured more than two times, using MAP TDR or MAP2 TDR with "Activate Multilink(Dual) Mode" option will generate collision as it is not expecting more than two BEGIN messages. Use of MAP Multi Leg TDR builder is bypassing this as it is able to correlate two and more BEGIN messages in same xDR.