![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 2159795.1 : How to Replace a Netra SPARC S7-2 LED Board [VCAP]
Oracle Confidential PARTNER - Available to partners (SUN). Reason: FRU part Applies to:Netra SPARC S7-2 - Version All Versions and laterInformation in this document applies to any platform. GoalHow to Replace a Netra SPARC S7-2 LED Board
*********************************************************************************************************** ESD Caution:
Contamination Caution:
SolutionDISPATCH INSTRUCTIONS DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc). If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return FRU just as the new FRU was packaged, to avoid any damages during shipping.
Note: A data backup is not a prerequisite but is a wise precaution.
Customer should perform an orderly and graceful shutdown of applications and OS to get the OpenBoot PROM prompt. Then power off the server and remove the AC power cords from the system. WHAT ACTION DOES THE ENGINEER NEED TO TAKE: Remove LED Board 1. Prepare the server for service. a. Power off the server and disconnect the power cords from the power supplies. Caution - Components inside the chassis might be hot. Use caution when servicing components inside the chassis.
2. Remove server top cover: a. Open the server top cover by pressing and holding down the top cover release button and then use the recessed area to slide the top cover toward the rear of the server (about 0.5 inches (12.7 mm)). 3. Open the front bezel. 4. Remove all Fan Modules. 5. Remove the Fan Tray. 6. Disconnect the disk backplane cables & rotate the Drive Cage to the service position. 7. Remove the USB cable from the PSU duct's channel & then remove the PSU duct. 8. Loosen the cables from the main air duct assembly. 9. Loosen the left thumb screw bracket, slide it forward to remove, & then remove the air duct. 10. Remove the cables from the cable tie to allow access to the LED board's connector on the motherboard. 11. Disconnect the LED Board cable from the motherboard. 12. Remove the left LED indicator module: a. Remove the two No. 2 Phillips screws that secure the LED indicator module to the server front panel.
Install Left LED Indicator Module 1. Position the LED on the server front panel. 2. Insert and tighten the two No. 2 Phillips screws to secure the LED indicator module to the server front panel. 3. Reconnect the LED board cable to the motherboard. 4. Connect the cables from the cable tie. 5. Place the main air duct assembly in position. 6. Place the left thumb screw bracket in position, slide it back, then tighten the thumb screw. 7. Fasten the disk cables to the Air Duct. 8. Install the PSU air duct & then route the USB cable in it's channel. 9. Rotate the Drive Cage to the operational position & reconnect all cables to the front disk backplane. 10. Install the fan tray 11. Install all fan modules 12. Close the front bezel. 13. Install the server top cover. Place the server top cover on the chassis and slide the top cover toward the front of the server (about 0.5 inches (12.7 mm)) until you hear the top cover release button lock into place. 14. Return the Server to operation. a. Remove any anti-static measures that were used. OBTAIN CUSTOMER ACCEPTANCE
Attachments This solution has no attachment |
||||||||||||
|