![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 2159155.1 : Pillar Axiom: How to determine the primary RAID Controller
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Pillar Axiom 600 Storage System - Version All Versions and laterInformation in this document applies to any platform. GoalHow to determine the Primary RAID controller from the brick console. Solution
FCRoot>shhm
Hardware Mode: Board Level 12 FC Gen2 650 FPGA Version F8 Ok GPIO Status 0000-00FD Brix Type 03 (FC) Start Mode 03 Normal User Mode 00 No User Input Startup State 0F Fini Reset Src 00 Unknown Mode Flags 4C HeartBeat Comp_Detected mf_Online Comp Mode Flags 4F Slot_1 Primary HeartBeat Comp_Detected mf_Online Run Level 30 Normal Comp Run Level 30 Normal Token Flags 00 None Data Segment Addr A410-0004 Size 31457276. Free Code Space 3824. bytes Below 1 MByte Pnet Status Got Link. Jbod (01) TW (01) Slot (00) Boot ( 4100.) Main ( 4600.) FPGA (0B) HBs Received: 30477529. Sync's lost: 0. Total Missing: 957. Current Missing: 0. Ignore Flag: 0. hbState: 0001_0000
This is the other RC in same FC brick shows that this FC RAID Controller is the primary because Primary flag set in "Mode Flags" section which means "I am primary": RAID>shhm
Hardware Mode: Board Level 12 FC Gen2 650 FPGA Version F8 Ok GPIO Status 0000-00FD Brix Type 03 (FC) Start Mode 03 Normal User Mode 00 No User Input Startup State 0F Fini Reset Src 00 Unknown Mode Flags 4F Slot_1 Primary HeartBeat Comp_Detected mf_Online Comp Mode Flags 4C HeartBeat Comp_Detected mf_Online Run Level 30 Normal Comp Run Level 30 Normal Token Flags 01 Token Data Segment Addr A410-0004 Size 31457276. Free Code Space 3824. bytes Below 1 MByte Pnet Status Got Link. Jbod (01) TW (01) Slot (01) Boot ( 4100.) Main ( 4600.) FPGA (0B) HBs Received: 64308445. Sync's lost: 1. Total Missing: 3498. Current Missing: 0. Ignore Flag: 0. hbState: 0001_0000 Here is example for SATA brick: RAID>shhm Board Level 02 PBC2 The above example shows that this SATA RAID Controller is the primary because Primary flag set in "Mode Flags" section which means "I am primary".
This is the companion RAID controller in same brick which says it's companion is the primary: RAID>shhm Board Level 02 PBC2 References<NOTE:1496018.1> - Pillar Axiom: How to replace a Brick Disk Drive using Guided Maintenance [VCAP]<BUG:23756528> - MULTIPLE FAILED DRIVES ON BRICK-010. BRICK-10 RC 1 IN BOOTING. LUN OFFLINE Attachments This solution has no attachment |
||||||||||||||||
|