![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||
Solution Type Technical Instruction Sure Solution 2155534.1 : How to Replace a SPARC S7-2L Memory DIMM [VCAP]
Applies to:SPARC S7-2L - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. GoalHow to Replace a SPARC S7-2L Memory DIMM ******************************************************************************* ESD Caution:
Contamination Caution:
Solution DISPATCH INSTRUCTIONS WHAT SKILLS ARE REQUIRED?: DAMAGE ALERT: Perform a visual inspection of the replacement part to make sure that there are no damaged components, connectors, bent pins, damaged packages during shipping, etc). If the part is damaged, don't install it into the system, order a new part. Handle with caution and package carefully the return part to avoid any damages during shipping.
Note: A data backup is not a prerequisite but is a wise precaution.
Customer should perform an orderly and graceful shutdown of applications and OS to get the OpenBoot PROM prompt. Then power off the server and remove the AC power cords from the system. Remove Memory DIMM 1. Prepare the server for service. a. Power off the server and disconnect the power cords from the power supplies. Caution - Components inside the chassis might be hot. Use caution when servicing components inside the chassis.
2. Open fan door and remove server top cover: a. Open the fan door by sliding the fan door latches forward and swinging the door up to the open position. 3. Remove clear plastic air duct assembly: 4. Press the blue memory remind button (located on the motherboard between CMP1 DIMMs and the side of the chassis) to identify the DIMM(s) that need to be replaced. 5. Push down on the ejector tabs on each side of the DIMM until the DIMM is released. Caution - DIMMs and heat sinks on the motherboard may be hot.
6. Grasp the top corners of the faulty DIMM and lift it out of its slot. 7. Place the DIMM on an antistatic mat. 8. Repeat Step 5 through Step 7 for any other DIMM(s) you intend to remove. Install Memory DIMM 1. Unpack the replacement DIMM(s) and place them on an antistatic mat. 2. Ensure that the ejector tabs on the connector that will receive the DIMM are in the open position. 3. Align the DIMM notch with the key in the connector. Caution - Ensure that the orientation is correct. The DIMM might be damaged if the orientation is reversed.
4. Push the DIMM into the connector until the ejector tabs lock the DIMM in place. Note - If the DIMM does not easily seat into the connector, check the DIMM’s orientation.
5. Repeat Step 2 through Step 4 until all new DIMMs are installed. 6. Install the server top cover and close the fan door: a. Close the fan door by swinging the door down to the closed position and hearing the latches latch. 7. Return the Server to operation. a. Remove any anti-static measures that were used. Boot system and monitor boot sequence for errors. Test functionality of system: PARTS NOTE: REFERENCE INFORMATION:
Attachments This solution has no attachment |
||||||||||||
|