Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2153449.1
Update Date:2017-09-12
Keywords:

Solution Type  Technical Instruction Sure

Solution  2153449.1 :   T10000 - How to Disable Standard Label Protection Feature on T10000 Tape Drives (FSC 33F0)  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
  • Sun StorageTek T10000B Tape Drive
  •  
  • StorageTek T10000D Tape Drive
  •  
  • Sun StorageTek SL8500 Modular Library System
  •  
  • StorageTek T10000C Tape Drive
  •  
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Goal
Solution
References


Created from <SR 3-12853608561>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Sun StorageTek T10000 Tape Drive - Version All Versions and later
Sun StorageTek T10000A Tape Drive - Version All Versions and later
Sun StorageTek T10000B Tape Drive - Version All Versions and later
StorageTek T10000C Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Goal

T10000 drives come with the configurable Standard Label Protection feature described in the following document: 9x40/T10000 - Standard Label Protect Feature (Doc ID 1478119.1)

Drives may be reporting invalid Vol ID through FSC 33F0:

FSC: 33F0 HS_FSC_INVALID_VOLID
MIM Code: NONE
FRU: STATUS ONLY CONF: 100%
Summary: |INVALID UCODE |RETURN CODE | *** |
Field Text: Failed check for valid Vol-Id at block 0. This is a Perm, and is a configurable option. Enable this check using the Label Protection menu option on the front panel.

If this is causing issues with using media, especially if it is enabled only on some drive, the Standard Label protection feature may be turned off or on using the Virtual Operator Panel (VOP) software.
 

Solution

To turn off Standard Label Protection:

1. Log into the drive with VOP.
2. Set the drive offline (Drive Operations → Set Offline)
3. Go to Configure → Drive Data...
4. Next to "Standard Label protect" select "No", make sure the checkbox under "Update" is selected and click "Commit"
5. Drive will reboot. When it does, it will be online.
 

To enable Standard Label Protection:

1. Log into the drive with VOP.
2. Set the drive offline (Drive Operations → Set Offline)
3. Go to Configure → Drive Data...
4. Next to "Standard Label protect" select "Yes", make sure the checkbox under "Update" is selected and click "Commit"
5. Drive will reboot. When it does, it will be online.

References

<NOTE:1478119.1> - 9x40/T10000 - Standard Label Protect Feature
<NOTE:1548329.1> - 9940B- Drive Went to Not Communicating Due to FSC33F0 SNO