Solution Type  Technical Instruction Sure

Solution  2152760.1 :   Topology Configuration Alarms After 2.2.9 Firmware Upgrade  


Related Items
  • Oracle Communications Policy Management
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Broadband Network Solutions>SN-SND: Tekelec Policy
  •  




In this Document
Goal
Solution
References


Created from <SR 3-12598468111>

Applies to:

Oracle Communications Policy Management - Version POLICY 12.0.0 and later
Information in this document applies to any platform.

Goal

On : POLICY 12.0.0 version, Wireless (Production)

2 systems are reporting "Topology is configured incorrectly" after firmware upgrade to 2.2.9. 

Solution

1. SS to Primary Active CMP as root
2. Execute the following command:
  
iload -v -t -fname -fvalue -fallowPgmChg -fcomment StringParam <<'!'
cm.ha.pathValidationMode|promiscuous|Yes|Restraining COMCOL alarms about unknown IP addresses
!

References

<BUG:23239410> - PAIR 3 - TOPOLOGY CONFIGURATION ALARMS AFTER 2.2.9 FIRMWARE UPGRADE