Asset ID: |
1-71-2151989.1 |
Update Date: | 2016-06-27 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2151989.1
:
The HIPR2 Card Serial Number is Missing Under "rtrv-stp" since R46.2
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
|
In this Document
Created from <SR 3-12825126521>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EAGLE 46.2 and later
Information in this document applies to any platform.
Goal
After the R46.2 upgrade, we saw that serial number of the HIPR2 cards are missing under "rtrv-stp".
Solution
This issue is indeed reported since the release R46.0.
This is the Bug 20733304 - SR: R46.2_ST:Part #, Rev, Serial # and Type missing for HIPR2 in rtrv-stp.
This is fixed in release 46.3.0.0.0-66.4.0.
In the meantime, to get the P/N and S/N of any HIPR2 card, run the command "rtrv-bip:loc=".
References
<BUG:20733304> - SR: R46.2_ST:PART #, REV, SERIAL # AND TYPE MISSING FOR HIPR2 IN RTRV-STP.
Attachments