Solution Type Technical Instruction Sure Solution 2151620.1 : Oracle MiniCluster MC-S7: How to factory reset the entire system
How to restore a minicluster s7 engineered system back to factory settings. Used prior to re-configuring or re-provisioning a system or in case some sort of major problem occurs during customer self installation. In this Document
Applies to:MiniCluster S7-2 Hardware - Version All Versions to All Versions [Release All Releases]Oracle Solaris on SPARC (64-bit) Oracle MiniCluster S7-2 is a customer self install-able system and as such a factory reset procedure is required. GoalPerform a factory reset of the system.
Note: the Oracle MiniCluster S7-2 EIS document has an appendix covering the same topic.
Solution1. Prerequisites 2017-04-25 Installing MC-S7 software components with AI server can be done by setting up a laptop or other server. There is some internal information on this in item # 8 at the end of this document. I'll add some more details on this later as necessary. Oracle MiniCluster S7-2 Factory Reset Instructions 1. PrerequisitesIn case a given MiniCluster S7-2 requires a reset back to factory default image one will also need to refer to the Oracle MiniCluster S7-2 Software Download Center MOS Document ID 2153282.1 in order to download the correct factory reset ISO and necessary patches and bundles. Note that one will need to download all of the following patches for the desired release:
To locate the ISO image file simply download and unpack the required MiniCluster Factory Reset ISO patch bundle and look for a file with the naming convention of Oracle_Minicluster_AI_SPARC-MM-DD-YY-VV.iso from within patch bundle (where VV is latest version#) Extract all components from the patch and store the ISO image on an external NFS server that can be reached / resolved via the management network and share it. This share will be used to boot the ISO image for the installation as well as a staging area for the rest of the installation. If the "EEPROM Password" has been enabled either via MCMU BUI "System Security" -> "Security" Tab or via the CLI "mcmu security -e" setting, disable it before doing an ISO reset. If not, you will be prompted for the EEPROM password during the reset procedure and after setup is complete, MCMU will incorrectly show eeprom password as disabled. During MiniCluster MC-S7 factory reset, all passwords are reset to 'default' automatically with the exception of root user at service processor ILOM. During re-image one is prompted for the password and some users do not realize that the ILOM password did *not* get reset, and so the re-image fails. One must either reset the password to default before the re-image, or else use the correct password when prompted. This process will need to be done on both nodes of the cluster. Should a need arise to reset the ILOM user account info, please refer to Oracle MiniCluster MC-S7: Example of how to manually reset ILOM root password (Doc ID 2254209.1). Note that how to create and share NFS file systems on an NFS server is beyond the scope of this document. 2. General flow Recent improvements in the MC-S7 re-image/install process have simplified matters. In general the flow is for both nodes as follows:
3. Setting up re-imaging via ISO/ILOM redirection
->show /SP/services/kvms/ servicestate
/SP/services/kvms Properties: servicestate = enabled
-> set /SP/services/kvms/host_storage_device mode=remote
Set 'mode' to 'remote' -> show /SP/services/kvms/host_storage_device mode /SP/services/kvms/host_storage_device Properties: mode = remote
-> cd /SP/services/kvms/host_storage_device/remote
/SP/services/kvms/host_storage_device/remote -> ls /SP/services/kvms/host_storage_device/remote Targets: Properties: password = (none) server_URI = (none) username = (none) Commands: cd show -> set server_URI=nfs://1.2.3.57:/root/minicluster/Factory/Oracle_Minicluster_AI_SPARC-10-13-16-59.iso Note: the above steps can be performed from BUI as well. See the MC-S7 Administrator's guide or the internal only Enterprise Installation Standards EIS document for MC-S7 for more details.
When using ILOM storage redirection after the installation has completed go back to the Redirection Screen on the Windows / Linux system:
4. Installing the Oracle Minicluster S7-2 ISO
It is suggested to have four windows open with SSH connections, two per physical node ILOM (i.e. two windows for node1 and two windows for node2), with one window each for host console and one for ILOM interaction.
-> set /HOST/bootmode script="setenv auto-boot? false"
-> reset /SYS
-> start -f /HOST/console
NOTE: If you are resetting to SRU19 or below, use the following command. If you are using SRU19.5 ISO, please use the 2nd form of the boot comand below.
ISO version SRU12.5:
ok> boot rcdrom - install aimanifest=/var/tmp/mc-default-iso.xml profile=/var/tmp/mc-n1-profile.xml
ISO version SRU19.5 and above:
ok> boot rcdrom - install aimanifest=/.cdrom/auto_install/mc-default-iso.xml profile=/.cdrom/auto_install/mc-n1-profile.xml
Solaris console login:
WARNING: Can not verify signature on unsupported binary format
WARNING: Signature verification of boot-archive bootblk failed
“Can't open disk label package”
or “Can't open boot device”
+ -> reset /SP
Important Note
After installation is finished and if ILOM storage redirection was used do not forget to execute these last steps also documented in Section 3 above: When the installation has completed go back to the Redirection Screen on the Windows / Linux system:
-> set /SP/services/kvms/host_storage_device mode=miniroot
-> show /SP/services/kvms/host_storage_device mode status
/SP/services/kvms/host_storage_device Properties: mode = miniroot status = operational Restore auto-boot to true:
->set /HOST/bootmode script="setenv auto-boot? true"
5. Installing Core Components
-> start /HOST/console
# ipadm create-ip -t net2
# ipadm create-addr -t -a 1.2.3.4/24 net2
# route add default 1.2.3.1
#PermitRootLogin no
#CONSOLE=/dev/console
#svcadm restart svc:/network/ssh:default
root@mccn:~# cd /var/tmp
root@mccn:/var/tmp# gtar xvf mc-1.1.25.4-core.tar
# root@mccn:/var/tmp# cd mc-1.1.25.4/onsite
# root@mccn:/var/tmp/mc-1.1.25.4/onsite#./Install.sh
-> show /SP/cli
/SP/cli Targets: Properties: legacy_targets = disabled prompt = (none) timeout = 30 Commands: cd set show
-> set /SP/cli timeout=30
root@mccn1:~/mc-1.1.3/onsite# ./Install.sh
Installing MCMU toolkit. Boot environment before-mcmu created as snapshot of current BE. It will be removed when MCMU is installed Extracting files. Installing omctoolkit package. Packages to install: 2 Services to change: 4 Create boot environment: No Create backup boot environment: No DOWNLOAD PKGS FILES XFER (MB) SPEED Completed 2/2 5767/5767 28.4/28.4 10.3M/s PHASE ITEMS Installing new actions 6571/6571 Updating package state database Done Updating package cache 0/0 Updating image state Done Creating fast lookup database working Creating fast lookup database Done Updating package cache 2/2 Creating local repo Using sol-11_3-repo download. Uncompressing sol-11_3-repo_1of5.zip...done. Uncompressing sol-11_3-repo_2of5.zip...done. Uncompressing sol-11_3-repo_4of5.zip...done. Uncompressing sol-11_3-repo_5of5.zip...done. Repository can be found in /repo. Using sol-11_3_8_3_0-incr-repo download. IPS repository exists at destination /repo Current version: 0.175.3.1.0.5.0 Adding packages to existing repository. Uncompressing sol-11_3_8_3_0-incr-repo_1of3.zip...done. Uncompressing sol-11_3_8_3_0-incr-repo_2of3.zip...done. Uncompressing sol-11_3_8_3_0-incr-repo_3of3.zip...done. Repository can be found in /repo. Initiating repository rebuild. Local repository created successfully Publisher set to /repo Clean mcpool 2.17T 190K 2.17T 0% 1.00x ONLINE - Creating zone appzonetemplate template /mcpool/appzonetemplate must not be group readable. /mcpool/appzonetemplate must not be group executable. /mcpool/appzonetemplate must not be world readable. /mcpool/appzonetemplate must not be world executable. changing zonepath permissions to 0700. Progress being logged to /var/log/zones/zoneadm.20160506T004155Z.appzonetemplate.install Image: Preparing at /mcpool/appzonetemplate/root. Install Log: /system/volatile/install.3028/install_log AI Manifest: /tmp/manifest.xml.t1aa5f SC Profile: /usr/share/auto_install/sc_profiles/enable_sci.xml Zonename: appzonetemplate Installation: Starting ... Creating IPS image Startup linked: 1/1 done Installing packages from: solaris origin: http://localhost:1008/solaris/bbb612b800c4a05fe489e22179376fa4cb0b1970/omc origin: http://localhost:1008/omc/3b27ec6dc20835df755859ff9015985749646692/ DOWNLOAD PKGS FILES XFER (MB) SPEED Completed 405/405 74503/74503 528.3/528.3 10.1M/s PHASE ITEMS Installing new actions 97847/97847 Updating package state database Done Updating package cache 0/0 Updating image state Done Creating fast lookup database working \ Creating fast lookup database Done Updating package cache 2/2 Installation: Succeeded Note: Man pages can be obtained by installing pkg:/system/manual done. Done: Installation completed in 195.937 seconds. Next Steps: Boot the zone, then log into the zone console (zlogin -C) to complete the configuration process. Log saved in non-global zone as /mcpool/appzonetemplate/root/var/log/zones/zoneadm.20160506T004155Z.appzonetemplate.ins tall Creating zone dbzonetemplate template /mcpool/dbzonetemplate must not be group readable. /mcpool/dbzonetemplate must not be group executable. /mcpool/dbzonetemplate must not be world readable. /mcpool/dbzonetemplate must not be world executable. changing zonepath permissions to 0700. Progress being logged to /var/log/zones/zoneadm.20160506T004527Z.dbzonetemplate.install Image: Preparing at /mcpool/dbzonetemplate/root. Install Log: /system/volatile/install.4088/install_log AI Manifest: /tmp/manifest.xml.jraG9h SC Profile: /usr/share/auto_install/sc_profiles/enable_sci.xml Zonename: dbzonetemplate Installation: Starting ... Creating IPS image Startup linked: 1/1 done Installing packages from: solaris origin: http://localhost:1008/solaris/bbb612b800c4a05fe489e22179376fa4cb0b1970/ omc origin: http://localhost:1008/omc/3b27ec6dc20835df755859ff9015985749646692/ DOWNLOAD PKGS FILES XFER (MB) SPEED Completed 255/255 46791/46791 323.5/323.5 10.9M/s PHASE ITEMS Installing new actions 63200/63200 Updating package state database Done Updating package cache 0/0 Updating image state Done Creating fast lookup database Done Updating package cache 2/2 Installation: Succeeded Note: Man pages can be obtained by installing pkg:/system/manual done. Done: Installation completed in 126.634 seconds. Next Steps: Boot the zone, then log into the zone console (zlogin -C) to complete the configuration process. Log saved in non-global zone as /mcpool/dbzonetemplate/root/var/log/zones/zoneadm.20160506T004527Z.dbzonetemplate.insta ll Progress being logged to /var/log/zones/zoneadm.20160506T004734Z.acfskz.install pkg cache: Using /var/pkg/publisher. Install Log: /system/volatile/install.4600/install_log AI Manifest: /tmp/zoneadm4338.Bea4Zi/devel-ai-manifest.xml SC Profile: /var/opt/oracle.minicluster/setup/schema/acfskz-sysconfig.xml Installation: Starting ... Creating IPS image Startup: Retrieving catalog 'solaris' ... Done Startup: Caching catalogs ... Done Startup: Refreshing catalog 'omc' ... Done Startup: Refreshing catalog 'solaris' ... Done Startup: Caching catalogs ... Done Installing packages from: solaris origin: file:///repo/ omc origin: file:///var/tmp/omctoolkit.p5p/ Startup: Refreshing catalog 'omc' ... Done Startup: Refreshing catalog 'solaris' ... Done Planning: Solver setup ... Done Planning: Running solver ... Done Planning: Finding local manifests ... Done Planning: Fetching manifests: 1/441 0% complete Planning: Fetching manifests: 441/441 100% complete Planning: Package planning ... Done Planning: Merging actions ... Done Planning: Checking for conflicting actions ... Done Planning: Consolidating action changes ... Done Planning: Evaluating mediators ... Done Planning: Planning completed in 50.44 seconds The following licenses have been accepted and not displayed. Please review the licenses for the following packages post-install: consolidation/osnet/osnet-incorporation Package licenses may be viewed using the command: pkg info --license Download: 0/87010 items 0.0/512.9MB 0% complete Download: 37647/87010 items 247.8/512.9MB 48% complete (9.7M/s) Download: Completed 512.91 MB in 8.19 seconds (3.5M/s) Actions: 1/110681 actions (Installing new actions) Actions: 22517/110681 actions (Installing new actions) Actions: 31427/110681 actions (Installing new actions) Actions: 39240/110681 actions (Installing new actions) Actions: 47089/110681 actions (Installing new actions) Actions: 54594/110681 actions (Installing new actions) Actions: 61662/110681 actions (Installing new actions) Actions: 69446/110681 actions (Installing new actions) Actions: 77644/110681 actions (Installing new actions) Actions: 85378/110681 actions (Installing new actions) Actions: 93820/110681 actions (Installing new actions) Actions: 101724/110681 actions (Installing new actions) Actions: 109058/110681 actions (Installing new actions) Actions: 109263/110681 actions (Installing new actions) Actions: Completed 110681 actions in 71.16 seconds. Done Installation: Succeeded Done: Installation completed in 198.584 seconds. Starting factory setup script. Please review /var/log/omc-factory.log for details Creating /var/opt/oracle.minicluster/sfw/silentgi .. Creating /var/opt/oracle.minicluster/sfw/oracle-eshm .. Creating /var/opt/oracle.minicluster/sfw/oracle-emsi .. May 5 17:51:11 mccn1 root[5232]: Oracle MiniCluster : factory setup in progress. May 5 17:51:11 mccn1 root[5232]: [ID 702911 user.alert] Oracle MiniCluster : factory setup in progress. Broadcast Message from root (???) on mccn1 Thu May 5 17:51:11... Oracle MiniCluster v1.0 : Factory Setup ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ .. currently in progress. As part of factory setup, root becomes a role , and the system may get rebooted at the end of this exercise. Please connect as 'mcinstall' user after successful factory setup. Current IP recovery probe time setting PROTO PROPERTY PERM CURRENT PERSISTENT DEFAULT POSSIBLE ip _dup_recovery rw 300000 -- 300000 0-3600000 Setting duplicate IP recovery probe time to one second .. New IP recovery probe time setting PROTO PROPERTY PERM CURRENT PERSISTENT DEFAULT POSSIBLE ip _dup_recovery rw 100 100 300000 0-3600000 Creating an aggregated link for interconnect setup .. [INFO ] Log file path : mccn1:/var/opt/oracle.minicluster/setup/logs/omc_pvtconfig_v2_050516_175111.log [INFO ] Setting Aggregate link on Management Interconnect.. [INFO ] Verifying Setting of Aggregate link on Management Interconnect.. [INFO ] Setting Aggregate link on Management Interconnect.. Verified Successfully [INFO ] Setting Aggregate link on Management Interconnect.. Completed Creating mcinstall user .. [INFO ] Log file path : mccn1:/var/opt/oracle.minicluster/setup/logs/omc_crmcadmuser_v2_050516_175113.log [INFO ] Creating MiniCluster Administator users .. [INFO ] Creating Minicluster Administrator profile.. [INFO ] Creating mcadmin role... [INFO ] Creating mcadm user and assigning mcadmin as a role... [INFO ] Adding root as a role to mcinstall... [INFO ] Verifying MiniCluster Administator users .. [INFO ] Checking if mcadmin(role) , mcadm and mcinstall users exist... [INFO ] Checking if mcadmin is assigned as a role to mcadm... [INFO ] Checking if root is assigned as a role to mcinstall... [INFO ] Creating MiniCluster Administator users .. Verified Successfully [INFO ] Creating MiniCluster Administator users .. Completed Creating a system identifier .. [INFO ] Log file path : mccn1:/var/opt/oracle.minicluster/setup/logs/omc_sysid_v2_050516_175115.log [INFO ] Setting the System Identifier.. [INFO ] Verifying the System Identifier.. [INFO ] Setting the System Identifier.. Verified Successfully [INFO ] Setting the System Identifier.. Completed Secured by Default (SBD) settings for ILOM .. [INFO ] Log file path : mccn1:/var/opt/oracle.minicluster/setup/logs/omc_sbd_ilom_v2_050516_175118.log [INFO ] Secured by Default Settings.. [INFO ] Verifying Secured by Default Settings.. [INFO ] Secured by Default Settings.. Verified Successfully [INFO ] Secured by Default Settings.. Completed Check if multipathing was enabled .. Running OS command: prtconf -vc /devices/scsi_vhci |grep dev_link.*s2 Output: dev_link=/dev/dsk/c0t5000CCA02D0FAAD0d0s2 dev_link=/dev/rdsk/c0t5000CCA02D0FAAD0d0s2 dev_link=/dev/dsk/c0t5000CCA02D0FA18Cd0s2 dev_link=/dev/rdsk/c0t5000CCA02D0FA18Cd0s2 dev_link=/dev/dsk/c0t5000CCA02D0FD608d0s2 dev_link=/dev/rdsk/c0t5000CCA02D0FD608d0s2 dev_link=/dev/dsk/c0t5000CCA02D0F9F00d0s2 dev_link=/dev/rdsk/c0t5000CCA02D0F9F00d0s2 dev_link=/dev/dsk/c0t5000CCA02D0FC338d0s2 dev_link=/dev/rdsk/c0t5000CCA02D0FC338d0s2 dev_link=/dev/dsk/c0t5000CCA02D0FA03Cd0s2 dev_link=/dev/rdsk/c0t5000CCA02D0FA03Cd0s2 dev_link=/dev/dsk/c0t5000CCA05351B638d0s2 dev_link=/dev/rdsk/c0t5000CCA05351B638d0s2 dev_link=/dev/dsk/c0t5000CCA04E0E08E4d0s2 dev_link=/dev/rdsk/c0t5000CCA04E0E08E4d0s2 dev_link=/dev/dsk/c0t5000CCA05351AA98d0s2 dev_link=/dev/rdsk/c0t5000CCA05351AA98d0s2 dev_link=/dev/dsk/c0t5000CCA23B109E88d0s2 dev_link=/dev/rdsk/c0t5000CCA23B109E88d0s2 dev_link=/dev/dsk/c0t5000CCA23B10C2E8d0s2 dev_link=/dev/rdsk/c0t5000CCA23B10C2E8d0s2 dev_link=/dev/dsk/c0t5000CCA04E0D3358d0s2 dev_link=/dev/rdsk/c0t5000CCA04E0D3358d0s2 dev_link=/dev/dsk/c0t5000CCA05351B568d0s2 dev_link=/dev/rdsk/c0t5000CCA05351B568d0s2 dev_link=/dev/dsk/c0t5000CCA05351BA80d0s2 dev_link=/dev/rdsk/c0t5000CCA05351BA80d0s2 dev_link=/dev/dsk/c0t5000CCA05351B998d0s2 dev_link=/dev/rdsk/c0t5000CCA05351B998d0s2 dev_link=/dev/dsk/c0t5000CCA05351B4FCd0s2 dev_link=/dev/rdsk/c0t5000CCA05351B4FCd0s2 dev_link=/dev/dsk/c0t5000CCA23B10C8E4d0s2 dev_link=/dev/rdsk/c0t5000CCA23B10C8E4d0s2 dev_link=/dev/dsk/c0t5000CCA05351B9B8d0s2 dev_link=/dev/rdsk/c0t5000CCA05351B9B8d0s2 dev_link=/dev/dsk/c0t5000CCA05351AB84d0s2 dev_link=/dev/rdsk/c0t5000CCA05351AB84d0s2 dev_link=/dev/dsk/c0t5000CCA04E0E002Cd0s2 dev_link=/dev/rdsk/c0t5000CCA04E0E002Cd0s2 dev_link=/dev/dsk/c0t5000CCA23B0FB920d0s2 dev_link=/dev/rdsk/c0t5000CCA23B0FB920d0s2 dev_link=/dev/dsk/c0t5000CCA053558890d0s2 dev_link=/dev/rdsk/c0t5000CCA053558890d0s2 dev_link=/dev/dsk/c0t5000CCA05351B678d0s2 dev_link=/dev/rdsk/c0t5000CCA05351B678d0s2 dev_link=/dev/dsk/c0t5000CCA05351B788d0s2 dev_link=/dev/rdsk/c0t5000CCA05351B788d0s2 dev_link=/dev/dsk/c0t5000CCA04E0D26ECd0s2 dev_link=/dev/rdsk/c0t5000CCA04E0D26ECd0s2 dev_link=/dev/dsk/c0t5000CCA23B108B9Cd0s2 dev_link=/dev/rdsk/c0t5000CCA23B108B9Cd0s2 dev_link=/dev/dsk/c0t5000CCA05351B330d0s2 dev_link=/dev/rdsk/c0t5000CCA05351B330d0s2 dev_link=/dev/dsk/c0t5000CCA23B109C30d0s2 dev_link=/dev/rdsk/c0t5000CCA23B109C30d0s2 dev_link=/dev/dsk/c0t5000CCA05351B3A0d0s2 dev_link=/dev/rdsk/c0t5000CCA05351B3A0d0s2 dev_link=/dev/dsk/c0t5000CCA05351A8ECd0s2 dev_link=/dev/rdsk/c0t5000CCA05351A8ECd0s2 IO multipathing was enabled already. Destroying BE snapshot that was created right before the factory setup Notice: Compiled catalog for mccn1 in environment production in 0.05 seconds Notice: /Stage[main]/Main/Boot_environment[before-mcmu]/ensure: removed Notice: Finished catalog run in 5.00 seconds Done. May 5 17:52:50 mccn1 root[5572]: Oracle MiniCluster factory setup completed successfully by running omc-factorysetup script. May 5 17:52:50 mccn1 root[5572]: [ID 702911 user.alert] Oracle MiniCluster factory setup completed successfully by running omc-factorysetup script. Broadcast Message from root (???) on mccn1 Thu May 5 17:52:50... @@ [INFO] Oracle MiniCluster factory setup completed successfully by running omcfactorysetup script. @@ Done.
6. Install SFW components
remote-system# scp mc-1.1.25.4-sfw.tar mcinstall@<ipaddress>:/var/tmp/mc-1.1.25.4-sfw.tar
mcinstall@mccn1:/var/home/mcinstall % cd /var/opt/oracle.minicluster
mcinstall@mccn1:/var/opt/oracle.minicluster % gtar xvf /var/tmp/mc-1.1.25.4-sfw.tar mcinstall@mccn2:/var/home/mcinstall % cd /var/opt/oracle.minicluster
mcinstall@mccn2:/var/opt/oracle.minicluster % gtar xvf /var/tmp/mc-1.1.25.4-sfw.tar
#CONSOLE=/dev/console
#svcadm restart svc:/network/ssh:default
7. Resetting ILOM passwordRefernece the following document: Oracle MiniCluster MC-S7: Example of How to Manually Reset ILOM Root Password (Doc ID 2254209.1) 8. Installing servers with AI server
https://stbeehive.oracle.com/content/dav/st/MiniCluster%20Management%20Utility/Documents/AI%20manifest/mc-default-sonoma.xml
https://stbeehive.oracle.com/content/dav/st/MiniCluster%20Management%20Utility/Documents/AI%20manifest/mc-n1-profile.xml
sca15-1070-install$ pfexec /opt/cr-labtech/bin/cr-install add 00:10:e0:9a:04:76 sca15-1070-install-s11u3-SRU9-4-sparc sun4v -n ar01 -m mc-default-sonoma.xml -p ./mc-n1-profile.xml
where 00:10:e0:9a:04:76 is MAC address of net2 interface {0} ok set-defaults {0} ok setenv auto-boot? false {0} ok reset-all {0} ok setenv auto-boot? true {0} ok boot net2:dhcp - install
<END> References<NOTE:2153282.1> - Oracle MiniCluster S7-2: Software Download Center<NOTE:2254209.1> - Oracle MiniCluster MC-S7: Example of How to Manually Reset ILOM Root Password Attachments This solution has no attachment |
||||||||||||||||||||||||||||||||
|