Asset ID: |
1-71-2149419.1 |
Update Date: | 2018-01-01 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2149419.1
:
Bonded Interface Not Coming Up Post Hardware Replacement (NO-CARRIER,BROADCAST,MULTICAST,MASTER,UP)
Related Items |
- Oracle Communications Subscriber Data Management (SDM)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Broadband Network Solutions>SN-SND: Tekelec SDM
|
In this Document
Created from <SR 3-12729237901>
Applies to:
Oracle Communications Subscriber Data Management (SDM) - Version SDM 9.3 and later
Tekelec
Goal
Bonded interface not coming up post hardware replacement (NO-CARRIER,BROADCAST,MULTICAST,MASTER,UP)
Solution
Checked the bond status and found that link is down from both interfaces eth01 and eth02
-------
[root@xxx network-scripts]# cat /sys/class/net/eth01/carrier
0
[root@xxx network-scripts]# cat /sys/class/net/eth01/operstate
down
-------
On further investigation it was found that port XGE1/0/10 was down on both the switches. This was checked using command 'display interface brief' in both switches
XGE1/0/10 DOWN auto A T 135 bayX.ethY
After resetting the switch ports and bringing the ports up, problem was resolved.
Attachments
This solution has no attachment