Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2149401.1
Update Date:2017-11-12
Keywords:

Solution Type  Technical Instruction Sure

Solution  2149401.1 :   Errors On The Upgrade Documentation Of Eagle 46.2  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution
References


Created from <SR 3-12818322661>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 46.2 to EAGLE 46.2 [Release EAGLE 46.0]
Information in this document applies to any platform.

Goal

The upgrade documentation contains some errors. Sorry for the inconveniences.

Solution

act-upgrade:action=chkrel
Command entered at terminal #6.
;

sanity10812 15-11-25 12:17:06 EST EAGLE5 46.3.0.0.0-68.1.0
Copy Release data to ramdisk.
;

sanity10812 15-11-25 12:17:42 EST EAGLE5 46.3.0.0.0-68.1.0
Validate Release data on ramdisk.
;

sanity10812 15-11-25 12:17:42 EST EAGLE5 46.3.0.0.0-68.1.0
Command Failed: Error reported during Validation

Failed to CHKREL  error while running ACT-UPGRADE:ACTION=CHKREL:SRC=FIXED command.

This is documented under BUG: 22271372, which is fixed in R46.3. 

chkrel may fail, but it will not affect the functioning of upgrade. You can skip this error report and also continue with upgrade.

And Oracle recommends to use latest doc for the releases they are trying to upgrade. In their case, I can see they have upgraded from 45. to 46.2 so they must use E54340 Revision 2 only.
 

 

References

<BUG:22271372> - ACT-UPGRADE:ACTION=CHKREL FAILS WITH ERROR DURING VALIDATION.

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback