Goal

 T10000/9840 - How to Identify And Record Read/Write Related Settings.

Solution

Review and record any settings that could affect the read/write system.

Select the Drive Operations > Set Offline - this will take the drive offline
Select Configure > Drive Data > Fibre
Record the following settings:

Max Capacity
Max Receive Size
Set the drive for these settings:
Max Capacity - enabled
Max Receive Size - 2112
Commit your changes.