Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2148075.1
Update Date:2016-06-16
Keywords:

Solution Type  Technical Instruction Sure

Solution  2148075.1 :   Brocade Switch - EX_Port Is Disabled With Reason "Export in non base switch"  


Related Items
  • Brocade 5100 Switch
  •  
  • Brocade SAN Switch Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Switch>SN-DK: Brocade Switch
  •  




In this Document
Goal
Solution
References


Created from <SR 3-12645748551>

Applies to:

Brocade 5100 Switch - Version All Versions to All Versions [Release All Releases]
Brocade SAN Switch Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

Limitations and restrictions of Virtual Fabrics

All logical switches in a fabric should have the same base switch attribute. If a base switch is connected to a non-base switch, then you must take the appropriate action to resolve the conflict.

The following platforms are Virtual Fabrics-capable:
• Brocade 5100
• Brocade 5300
• Brocade 6510
• Brocade 6520
• Brocade 7800
• Brocade VA-40FC, in Native mode only
• Brocade DCX
• Brocade DCX-4S
• Brocade DCX 8510 family

Solution

Please refer to:

Brocade Fabric OS Administrator’s Guide -- Chapter 11: Limitations and restrictions of Virtual Fabrics

https://www.brocade.com/downloads/documents/product_manuals/B_SAN/FOS_AdminGd_v720.pdf

If you move existing EX_Ports or VEX_Ports to any logical switch other than the base switch,
these ports are automatically disabled

Base switch issues

All logical switches in a fabric should have the same base switch attribute. If a base switch is connected to a non-base switch,
then you must take the appropriate action to resolve the conflict.

Symptom :

EX_Port is disabled with reason "Export in non base switch".

Probable cause and recommended action

An EX_Port must be in the base switch.

Use the lsCfg --create command with the -b option to create a base switch.
Then use the lsCfg --config command with the -slot and -port options to move the port to the base switch. If the port is not intended to be used as an EX_Port, use the portCfgDefault command to reset the port to its default configuration.

   

From the switch supportshow file:

Index Port Address Media Speed State Proto
==================================================
........
23 23 011700 id N4 No_Light FC Disabled (ExPort in non base switch)

portshow 23
portDisableReason: ExPort in non base switch
portCFlags: 0x0
portFlags: 0x4021 PRESENT U_PORT EX_PORT DISABLED LED
LocalSwcFlags: 0x0
portType: 17.0
POD Port: Port is licensed
portState: 2 Offline
Protocol: FC
portPhys: 4 No_Light portScn: 2 Offline
port generation number: 90
state transition count: 2

portId: 011700
portIfId: 43020020
portWwn: 20:17:00:05:xx:xx:xx:xx
portWwn of device(s) connected:

 

To fix the EX_Port disabled issue run the command :

lscfg --config 128 -port 23

or

portCfgDefault 23

 

References

<NOTE:1003754.1> - How to Gather Brocade SupportSave or SupportShow Logs
<NOTE:1927554.1> - How To Delete a Logical Switch and Disable Virtual Fabric In Brocade SAN Switch

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback