![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 2148039.1 : SDP2 - How To Test T10000 Drive Dump Collection On SDP2
In this Document
Applies to:Sun StorageTek T10000 Tape Drive - Version All Versions to All Versions [Release All Releases]Sun StorageTek Multi-Drive Virtual Op Panel - Version 2.2 and later Information in this document applies to any platform. GoalHow to test drive dump collection on SDP2 SolutionYou will need SLC, PUTTY & MDVOP for this process to work and a tape you can use to load/unload (no writing will be done) This will either need to be done via Webex or the FE will need to be onsite.
1. login to the library via SLC SLC can be downloaded from the Oracle Software Delivery Cloud repository See SL500/SL3000/SL8500 - How to Download the SLConsole (SLC) (Doc ID 1511569.1)
2. login to the SDP2server via mdvop client tool (Please reference the SDP2 Installation guide in 1942540.1) (CSE Version has been used for this test, this does work with Sysadmin version also)
3. login to the SDP2server via putty as sdp2admin How To Restart SDP2 Services (Doc ID 2014464.1)
4. Locate the drive you will be testing via SLC.
5. Locate the Tape you will be using (move this to the CAP or system slots) 2093578.1
We will use Tape LAB013T2 for this example.
6. Click on the drive you will be testing in MDvop
7. Use RecvrMove to move the tape from the Cap or system slot to the drive.
8. Wait for the drive to load in MDVOP
9. Click unload drive from MDVOP
10. Wait for this to complete.
11. Use SLC RecvrMove to move the tape from the drive mouth to the system slot again.
12. Monitor the MDVOPserver.err file in /opt/Oracle/MdvopServer/logs to see the drive unload then look to the /home/sdp2admin/.mdvop/transcripts/observer_(Drive ip).0.txt file to see the log collection. The file will write the logs to the following location once completed /home/sdp2admin/.mdvop/vop_logs/T10000/<serial number of drive>/date
13. The log will be saved on the sdp2server for future log collections.
References<NOTE:1942540.1> - SDP2 Introduction<NOTE:2093578.1> - How to Move tape from a cell via SLC (SL-Console) using RecvrMove to the CAP and re-enter the cartridge(s). Attachments This solution has no attachment |
||||||||||||||||
|