![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2147479.1 : How to Use OPC In GTTSEL Parameters
In this Document
Created from <SR 3-12773752981> Applies to:Oracle Communications EAGLE (Hardware) - Version EAGLE 45.0 and laterTekelec GoalWe need to use the incoming OPC as a parameter for the GT translation. SolutionBelow are the possible commands that will be required to be run. May need to test this in lab first. Further details about the commands can be seen in Eagle STP Customer Documentation >> Commands Manual. You can download the command manual from following link: enable-ctrl-feat :partnum= 893014301 :fak= xxxxxxxx [get FAK from your account manager]
chg-ctrl-feat :partnum= 893014301 :status= on
ent-gttset :gttsn= :netdom= <itu/ansi>:settype=opc
ent-gttset :gttsn=test1 :netdom=itu :settype=opc
ent-gta:opc(n/i)=:gttsn=test1:.................................
chg-gta :gta= :gttsn= :cggtasn= -> Depending on release
chg-gta :gta= :gttsn= :optsn= -> Depending on release Note, depending on running release the parameter will be either cggtasn or optsn
chg-ls :lsn= :gttmode=
For OBSR we use acdcd as GTT mode
Attachments This solution has no attachment |
||||||||||||||
|