Asset ID: |
1-71-2147235.1 |
Update Date: | 2017-06-20 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2147235.1
:
About The Calculation Of Active Subscribers In KPI Dashboard
Related Items |
- Oracle Communications Policy Management
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Broadband Network Solutions>SN-SND: Tekelec Policy
|
In this Document
Created from <SR 3-12790525571>
Applies to:
Oracle Communications Policy Management - Version POLICY 11.5.2 and later
Information in this document applies to any platform.
Goal
On : POLICY 11.5.2 version, Wireless (Production)
About the calculation of Active Subscribers in KPI Dashboard
The count of Active Subscribers in MRAs and MPEs is different.
In the current system architecture, MPEcluster1 and MPEcluster2 are in the MRA's pool and it is expected MRA's Active Subscriber count = MPEcluster1's Active Subscribers count and MPEcluster2' Active Subscriber count, but it seems the result is different from the expectation.
Solution
The MRA Active Subscribers shows Aggregate CurrentMRABindingCount from all the MRA Clusters.
The MPE Active Subscribers shows Aggregate CurrentSessionCount (Active Sessions) from all the MPE Clusters.
MRA shows current binding count while MPE shows current Active sessions count.
The Active session count is greater in your case as some of the subscribers may have more than one active session which is expected and normal.
Note: Isolated MPE devices are not included in the aggregation counts.