![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2137447.1 : SL8500 - How to Remove and Replace HBN Card in SL8500 Library, ATR 2137447.1:2
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. GoalInstructions for removal and replacement of HBN card in SL8500. SolutionDISPATCH INSTRUCTIONS TIME ESTIMATE: 30 Minutes TASK COMPLEXITY: 2 FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS: WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?: Host operations must be halted before removing the HBN card. Request the operator to place the library offline to the Host/ACSLS. WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?: Refer to the SL8500 Service Manual for pictures and figures when taking the following actions. Removal of the HBN (Interlock Controller) Card: 1. Open the library rear doors. 2. Set PDU circuit breaker(s) to OFF (down). 3. Remove the center façade (see “Center Section: Two-Piece Façade Removal” on page 47 for a two piece, or “Center Section: Single Piece Façade Removal” on page 50 for a one piece) to access the HBN card (1) shown in FIGURE 1-138 on page 141. Note – 4. Disconnect all cables, one at a time: 5. Remove six T10 screws (1) shown in FIGURE 1-139 securing the card. 6. Remove the card. Replacement of the HBN (Interlock Controller) Card: 1. Position the replacement HBN Card into the mounting location. 2. Thread—but do not fully tighten—six T10 screws. Note – Do not tighten screws until all six are threaded. Otherwise, one or more screws may not start. 3. Tighten all six T10 screws to secure the card. 4. Connect all cables to appropriate receptacles (J500 through J508). Note – 5. Set PDU circuit breaker(s) to ON (up) and allow library to initialize. 6. Perform “HBN Card (Interlock Controller) Verification” on page 283. 7. Re-install the center façade (see “Center Section: Two Piece Façade Replacement” on page 49 for a two piece, or “Center Section: Single Piece Façade Replacement” on page 52 for a one piece).
OBTAIN CUSTOMER ACCEPTANCE PARTS NOTE: SL8500 Full Components List, https://mosemp.us.oracle.com/handbook_internal/Systems/SL8500/components.html REFERENCE INFORMATION: SL8500 Service Manual, http://amomv0115.us.oracle.com/archive/cd_ns/E23728_17/index.html Attachments This solution has no attachment |
||||||||||||||
|