Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2137447.1
Update Date:2018-04-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  2137447.1 :   SL8500 - How to Remove and Replace HBN Card in SL8500 Library, ATR 2137447.1:2  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: TAPE-CAP VCAP
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Goal

Instructions for removal and replacement of HBN card in SL8500.

Solution

DISPATCH INSTRUCTIONS
WHAT SKILLS DOES THE FIELD ENGINEER/ADMINISTRATOR NEED?: Knowledge of the SL8500 Library

TIME ESTIMATE: 30 Minutes

TASK COMPLEXITY: 2

FIELD ENGINEER/ADMINISTRATOR INSTRUCTIONS:
PROBLEM OVERVIEW: HBN card is determined to be defective and requires replacement.

WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY?:  Host operations must be halted before removing the HBN card. Request the operator to place the library offline to the Host/ACSLS.

WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE?:

Refer to the SL8500 Service Manual for pictures and figures when taking the following actions.

Removal of the HBN (Interlock Controller) Card:

1. Open the library rear doors.

2. Set PDU circuit breaker(s) to OFF (down).

3. Remove the center façade (see “Center Section: Two-Piece Façade Removal” on page 47 for a two piece, or “Center Section: Single Piece Façade Removal” on page 50 for a one piece) to access the HBN card (1) shown in FIGURE 1-138 on page 141.

Note –
There are nine jacks on the HBN card: J500 through J508. J505 is connected only when the library contains the optional safety door.

4. Disconnect all cables, one at a time:
a. Inspect each cable for a label that matches the card jack.
b. Label any cables that are not already clearly labeled.

5. Remove six T10 screws (1) shown in FIGURE 1-139 securing the card.

6. Remove the card.

Replacement of the HBN (Interlock Controller) Card:

1. Position the replacement HBN Card into the mounting location.

2. Thread—but do not fully tighten—six T10 screws.

Note – Do not tighten screws until all six are threaded. Otherwise, one or more screws may not start.

3. Tighten all six T10 screws to secure the card.

4. Connect all cables to appropriate receptacles (J500 through J508).

Note –
All connectors are either different or keyed differently.  J505 is connected only when the library contains the optional safety door.

5. Set PDU circuit breaker(s) to ON (up) and allow library to initialize.

6. Perform “HBN Card (Interlock Controller) Verification” on page 283.

7. Re-install the center façade (see “Center Section: Two Piece Façade Replacement” on page 49 for a two piece, or “Center Section: Single Piece Façade Replacement” on page 52 for a one piece).

 

OBTAIN CUSTOMER ACCEPTANCE
WHAT ACTION DOES THE FIELD ENGINEER/ADMINISTRATOR NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE?: Request the operator to place the library online to the Host/ACSLS.

PARTS NOTE: SL8500 Full Components List, https://mosemp.us.oracle.com/handbook_internal/Systems/SL8500/components.html

REFERENCE INFORMATION: SL8500 Service Manual, http://amomv0115.us.oracle.com/archive/cd_ns/E23728_17/index.html


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.