![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Technical Instruction Sure Solution 2135990.1 : What Are the Steps to Perform on NSP PIC Before an Eagle Upgrade?
In this Document
Created from <SR 3-12622450466> Applies to:Oracle Communications Performance Intelligence Center (PIC) Software - Version 4.1 and laterInformation in this document applies to any platform. GoalWhat are the steps to perform on NSP PIC before an Eagle upgrade to ensure a proper operation of the monitoring? SolutionBefore Eagle upgradeAll IMF must be synced in NSP CCM and no error must be displayed. Once this has been ensured, NSP backup must be done, verified and copied to a safe place. It is also recommended to capture iFoStat, linkDisp, routeDisp for all IMF servers. After Eagle upgradeAll IMF must be synced in NSP CCM. This does not prevent Eagle/PIC compatibility issue to happen. Report to PIC release notes for PIC/Eagle compatibility.
Attachments This solution has no attachment |
||||||||||||||||||
|