Asset ID: |
1-71-2135549.1 |
Update Date: | 2016-05-13 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2135549.1
:
SPR SDM Faulty Code 7058 In Read Operation During Provisioning Intermittent Failures
Related Items |
- Oracle Communications Subscriber Data Management (SDM)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Broadband Network Solutions>SN-SND: Tekelec SDM
|
In this Document
Created from <SR 3-12495310741>
Applies to:
Oracle Communications Subscriber Data Management (SDM) - Version SDM 9.3 and later
Information in this document applies to any platform.
Goal
Why are we experiencing intermittent Error Code 7058 while we are provisioning ?
Solution
The issue is that you are reaching the system limit for the amount of connections.
From /blue/var/log/WebCI.out, we see a pattern of multiple connections being made followed by the Exception error:
SESSION: Connected to 169.254.1.20, port: 62001, ip: xx.xx.11.26, user: provisioning, ID: 3
SESSION: Connected to 169.254.1.20, port: 62001, ip: xx.129.150.72, user: provisio_lig, ID: 5
SESSION: Connected to 169.254.1.20, port: 62001, ip: xx.2.49.73, user: provisio_lig, ID: 3
Exception too many connections openned!!!
The Error code 7058 is because there are too many SOAP connections opened. This error repeats throughout the log file as the limit is reached.
The product parameters are discussed in Appendix 2 of
Oracle® Communications
Subscriber Data Management
Release Notes
Release 9.3
910-6891-001 Revision P
This is available as part of the product documentation online.
excerpt - "45 simultaneous sessions may be used" and Max number of endpoints (provisioning clients) is 7.
Please refer to the document for more information.
Attachments
This solution has no attachment