Solution Type Technical Instruction Sure Solution 2129458.1 : Enable Hardware Acceleration Flag for Exalytics Machines
In this Document
Created from <SR 3-12524846851> Applies to:Exalytics In-Memory Machine X3-4 - Version All Versions to All Versions [Release All Releases]Exalytics In-Memory Machine X4-4 - Version All Versions to All Versions [Release All Releases] Exalytics In-Memory Machine X5-4 - Version All Versions to All Versions [Release All Releases] Exalytics In-Memory Machine X2-4 - Version All Versions to All Versions [Release All Releases] Oracle Exalytics T5-8 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. GoalHow to Enable the Hardware Acceleration Flag in Exalytics Machines? SolutionTo enable Hardware Acceleration flag in Exalytics, edit the single entry in
Change the parameter from: <bi:hw-acceleration>false</bi:hw-acceleration> To: <bi:hw-acceleration>true</bi:hw-acceleration> For installations of OBIEE 11G, setting the mbean property, effectively sets the hardware acceleration flag in the centralized config file (biee-domain.xml), which in turn propagates to all components (OBIS, OBIPS, essbase) the hardware flag in their respective config files.
During Installation if the user missed to select this option during Installation the entry needs to be done manually. If the user selects the checkbox, the installer calls the MBean "oracle.biee.admin:type=BIDomain,group=Service" and sets the property "HardwareAcceleration" to "1" (True) One can also verify the above configuration files to make sure it is set to "true" only then the true power of Exalytics Server can be realized. For installations above 12c, it might be required that this parameter may be turned to "true" manually and the above mentioned steps needs to be done.
References<BUG:21288687> - HARDWARE ACCELERATION FLAG NOT SET FOR 12C INSTALL<BUG:21288756> - 12C OBIEE INSTALLER NEEDS OPTION FOR EXALYTICS IN MEMORY OPTION Attachments This solution has no attachment |
||||||||||||||||
|