Solution Type Technical Instruction Sure Solution 2127688.1 : What Are the Diameter Message That Can Be Monitored by Integrated Diameter Intelligence Hub ?
In this Document
Created from <SR 3-12379777211> Applies to:Oracle Communications Diameter Signaling Router (DSR) - Version DSR 6.0 and laterInformation in this document applies to any platform. GoalWhat Are the Diameter Message That Can Be Monitored by Integrated Diameter Intelligence Hub (iDIH) ? SolutionThe IDIH works with only route-able diameter messages. The IDIH will not process any DWx, DPx or CEx type messages since they are non-routable. For example, trying to view CER/CEA (Capabilities-Exchange-Request/Capabilities-Exchange-Answer) and DWR/DWA (Device-Watchdog-Request/Device-Watchdog-Answer) with the iDIH is not possible. Attachments This solution has no attachment |
||||||||||||||
|