![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||
Solution Type Technical Instruction Sure Solution 2126486.1 : SL8500/SL3000: How To Display The Drive Check code
In this Document
Applies to:Sun StorageTek 9840 Tape Drive - Version Not Applicable and laterSun StorageTek T10000 Tape Drive - Version All Versions and later Sun Storage SL8500 Modular Library System - Version Not Applicable and later Sun Storage SL3000 Modular Library System - Version Not Applicable and later Sun StorageTek 9940 Tape Drive - Version Not Applicable and later Information in this document applies to any platform. GoalDescribe the process needed to display the drive Operator Panel message. SolutionConnect SLC to the library. Under the Drives heading select the drive you need to view. Click on the drive to select it. Click on the Display Tab. Look at the Drive Display Data line to see the current message on the display. If it begins with CK xxxx, where xxxx is a 4 digit Fault Symptom Code (FSC), then the drive is failing bring up diagnostics. You can look up the description of the FSC using VOP.
Attachments This solution has no attachment |
||||||||||||||
|