Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2122432.1
Update Date:2016-04-07
Keywords:

Solution Type  Technical Instruction Sure

Solution  2122432.1 :   UAM 0002 GPL SYSTEM BLIXP Card is not running approved GPL  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec Eagle 5
  •  




In this Document
Goal
Solution
   Here is the display results  :


Created from <SR 3-12412943571>

Applies to:

Oracle Communications EAGLE (Software) - Version EAGLE 3x.x and later
Information in this document applies to any platform.

Goal

Eagle is showing several GPL (generic program load) alarms :

8255.0002 * GPL SYSTEM BLCPLD Card is not running approved GPL
16-03-23 00:10:40
8256.0002 * GPL SYSTEM IMTPCI Card is not running approved GPL
16-03-23 00:10:40
8258.0002 * GPL SYSTEM PLDPMC1 Card is not running approved GPL
16-03-23 00:10:40
8259.0002 * GPL SYSTEM BLBEPM Card is not running approved GPL
16-03-23 00:10:40
8262.0002 * GPL SYSTEM BLVXW6 Card is not running approved GPL
16-03-23 00:10:40
8267.0002 * GPL SYSTEM BLDIAG6 Card is not running approved GPL
16-03-23 00:10:40
8268.0002 * GPL SYSTEM BLIXP Card is not running approved GPL
16-03-23 00:10:40

 

Solution

1. Two cards listed in GPL alarms are not configured in the Eagle, so I suppose they are spare cards simply powered by the Eagle : 1101 and 2106.
Please remove them from the Eagle.

2. Two other cards have a true GPL alarm : 4111 and 5305.
Please enter the below commands to clear the alarms :

- rept-stat-card:mode=full:loc=4111
- rept-stat-card:mode=full:loc=5305
- rept-stat-gpl:gpl=blixp
- chg-trm:trm=:card=yes:sa=yes:dbg=yes
- flash-card:code=appr:force=yes:loc=4111
- flash-card:code=appr:force=yes:loc=5305
wait for the message display "card has been flashed" or something equivalent
- rept-stat-gpl:gpl=blixp
- rept-stat-card:loc=4111
- rept-stat-card:loc=5305
- rept-stat-gpl

  Here is the display results  :

> flash-card:code=appr:force=yes:loc=4111

    eaglestp 16-03-31 09:30:51 IST  EAGLE5 44.0.5-64.34.26
    Flash Card: FLASH GPL(s) required to be downloaded on card 4111
    BLIXP    : Running version 134-034-012  Expected version 134-034-021

 

    eaglestp 16-03-31 09:30:51 IST  EAGLE5 44.0.5-64.34.26
    Flash Card: Cancelling links on card 4111.
    Flash Card: Inhibiting card 4111.

 

    eaglestp 16-03-31 09:31:38 IST  EAGLE5 44.0.5-64.34.26
    Flash Card: Downloading BLIXP on card 4111
    Flash Card: Card(s) will reset after the flash GPL download.

 

    eaglestp 16-03-31 09:34:00 IST  EAGLE5 44.0.5-64.34.26
    Flash Card: Card 4111 download BLIXP complete.

 

    eaglestp 16-03-31 09:34:43 IST  EAGLE5 44.0.5-64.34.26
    Flash Card: FLASH GPL(s) required to be activated on card 4111
    BLIXP    : Running inactive version 134-034-021

 

    eaglestp 16-03-31 09:34:43 IST  EAGLE5 44.0.5-64.34.26
    Flash Card: Activating BLIXP on card 4111

 

    eaglestp 16-03-31 09:34:44 IST  EAGLE5 44.0.5-64.34.26
    Flash Card: Card 4111 activation BLIXP complete.

 

    eaglestp 16-03-31 09:34:48 IST  EAGLE5 44.0.5-64.34.26
    Flash Card: Allowing card 4111

 

    eaglestp 16-03-31 09:35:51 IST  EAGLE5 44.0.5-64.34.26
    Command in Progress : Flash Card command in progress

 

    eaglestp 16-03-31 09:36:08 IST  EAGLE5 44.0.5-64.34.26
    Flash Card: Activating links on card 4111.

 

    eaglestp 16-03-31 09:36:41 IST  EAGLE5 44.0.5-64.34.26
    Command Completed.

 

    eaglestp 16-03-31 09:35:40 IST  EAGLE5 44.0.5-64.34.26
    8140.0096    CARD 4111 SS7HC         Card has been reloaded

 

 


 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback