![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 2119192.1 : How to Configure PIC to Have Association Name Instead of SCTP0, SCTP1, ... ?
In this Document
Created from <SR 3-12372917391> Applies to:Oracle Communications Performance Intelligence Center (PIC) Software - Version 7.1 and laterInformation in this document applies to any platform. GoalAssociation names are more meaningful than abstract names like SCTP0, SCTP1 etc. This document describes the steps that are needed to achieve it. SolutionCreate /usr/TKLC/TKLCixp/prod/lib/plugins/build/SCTPPathNaming.cnf on each IXP base server and fill it as per xDR_Builder Users Manual (909-2263-01). Find references of PIC 10.1.0 and PIC 10.1.5 documentation below. Despite what is written in the documentation, line with link name longer than 8 characters will be ignored, not truncated.
Make sure also the file has the appropriate rights and ownership -rw-r--r-- 1 cfguser cfg 0 Jan 19 15:48 LinkSetNaming.cnf
-rw-r--r-- 1 cfguser cfg 26088 Jan 19 15:48 q708.cnf -rw-r--r-- 1 cfguser cfg 26098 Nov 10 17:23 q708.cnf.default -rw-r--r-- 1 cfguser cfg 19316 Jan 19 15:48 q850.cnf -rw-r--r-- 1 cfguser cfg 16018 Nov 10 17:23 q850.cnf.default -rw-r--r-- 1 cfguser cfg 161845 Jan 17 17:04 SCTPPathNaming.cnf -rwxrwxrwx 1 cfguser cfg 4257 Nov 10 19:48 XbLoadSharing.cnf drwxr-xr-x 3 cfguser cfg 4096 Jan 17 14:44 XdrBuilders
References<NOTE:2032246.1> - PIC 10.1.5 xDR Builders Content User Manuals and Documentations<NOTE:1915467.1> - PIC 10.1.0 xDR Builders Content User Manuals and Documentations Attachments This solution has no attachment |
||||||||||||||||
|