Goal
Solution


Created from <SR 3-12091465401>

Applies to:

Sun StorageTek Auto Cartridge Sys Lib SW (ACSLS) - Version 8.0 and later
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Goal

Upgraded media slots on library but ACSLS was not updated.

How to update ACSLS slots.

Solution

Verify the ACSLS version with following command:
   in_get_version

Verify the free cells from following command:
   free_cells.sh –a

Command output:
   ACS 0

Total free cells = 599
  Allocated cells = 69
  Total cells = 668

Enter the tapes from the CAP.
In the case that the CAP status is automatic, no command is required from ACSLS.  Automatically the library will take the tapes.
In the case that the CAP status is manual, use the enter command to insert the tapes.


Verify the free_cells.sh –a command output
 

Nothing to do with ACSLS , in ACSLS software side it will take automatically.
 

 