![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Technical Instruction Sure Solution 2105781.1 : M10 / M12 - How to update XCP firmware
In this Document
Applies to:Fujitsu SPARC M12-2 - Version All Versions and laterFujitsu SPARC M12-2S - Version All Versions and later Fujitsu SPARC M12-1 - Version All Versions and later Fujitsu M10-4 - Version All Versions and later Fujitsu M10-4S - Version All Versions and later Information in this document applies to any platform. GoalCAP PROBLEM OVERVIEW: How to update XCP firmware To report errors or request improvements on this procedure, please go to My Oracle Support, and put a comment on Doc ID: 2105781.1
Notes:
Before starting the firmware update procedure, obtain the latest XCP firmware by downloading the appropriate patch to a location that is network-connected with the XSCF unit. Make sure to check Fujitsu M10-1/M10-4/M10-4S XSCF Control Package (XCP) Firmware Image Software Version Matrix Information (Doc ID 1554086.1) or Fujitsu M12-2/M12-2S XSCF Control Package (XCP) Firmware Image Software Version Matrix Information (Doc ID 2241012.1) to ensure you are using the latest available XCP version for the Fujitsu M10/M12 servers or the Fujitsu M10 PCI Expansion Unit. Consult "Fujitsu M10 PCI Expansion Unit Firmware Version Matrix Information (Doc ID 1924671.1)" to locate the proper firmware for the PCI Expansion Unit. Decompress the patch file in the network location on which you downloaded it, and which is reachable by the XSCF. SolutionDISPATCH INSTRUCTIONS WHAT SKILLS DOES THE ENGINEER NEED: M10/M12 Product Training/Experience TASK COMPLEXITY: 2 TIME ESTIMATE: 60 minutes (excluding possible all PPAR stop/start ) Sysadmin / FIELD ENGINEER INSTRUCTIONS WHAT STATE SHOULD THE SYSTEM BE IN TO BE READY TO PERFORM THE RESOLUTION ACTIVITY? : n/a WHAT ACTION DOES THE ENGINEER NEED TO TAKE:
The XCP firmware procedure exclusively runs on the active XSCF unit, if your system has multiple XSCFs, log in to the Master XSCF: 1. Updating firmware requires a user with either platadm or fieldeng privileges, run the showuser command to confirm having appropriate privileges 2. Run getflashimage, to import the new XCP firmware onto the main XSCF unit, example:
3. To confirm the XCP firmware image download was successful, run getflashimage -l 4. To check if firmware can be updated with PPARs running, run flashupdate -c check -m xcp -s 2320 5. To actually update the firmware, run flashupdate -c update -m xcp -s 2320 6. Wait until the XSCF serial port or showlogs monitor output indicates the update has completed: July 9 12:01:43 M10-1-0 Event: SCF:XCP update has been completed (XCP version=2320:last version=2290) 7. To determine if all PPARs need to be stopped and started (using XSCF poweroff and poweron command), you can check the information in "Fujitsu M10-1/M10-4/M10-4S XSCF Control Package (XCP) Firmware Image Software Version Matrix Information (Doc ID 1554086.1)" or Fujitsu M12-2/M12-2S XSCF Control Package (XCP) Firmware Image Software Version Matrix Information (Doc ID 2241012.1): - Compare the values listed for CMU, POST, OBP and Hypervisor for the XCP version used prior to installing, and for the XCP version that just finished installing OBTAIN CUSTOMER ACCEPTANCE WHAT ACTION DOES THE CUSTOMER NEED TO TAKE TO RETURN THE SYSTEM TO AN OPERATIONAL STATE: If PPARs need to stopped, make sure all PPARs successfully get started
======================== Other info ===================== REFERENCE INFORMATION:
Attachments This solution has no attachment |
||||||||||||||||
|