Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2104181.1
Update Date:2017-12-08
Keywords:

Solution Type  Technical Instruction Sure

Solution  2104181.1 :   HP LTO 4(External Dione card), 5 & 6 - How To Change The Drive IP Address.  


Related Items
  • HP LTO6 Tape Drive
  •  
  • HP LTO4 Tape Drive
  •  
  • HP LTO5 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Goal
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for Service Personnel

Applies to:

HP LTO6 Tape Drive - Version All Versions to All Versions [Release All Releases]
HP LTO4 Tape Drive - Version All Versions to All Versions [Release All Releases]
HP LTO5 Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Goal

This guide describes the process of changing the HP LTO 5 and 6 drive IP address(and the external Dione card, which was shipped with HP LTO4 drives connected in our encryption environment, OKM/KMS). HP LTO 5 and 6 drives are the only generations that are shipped with native Ethernet port. The port on the drive end is actually an iADT port, which needs a special converter cable, which comes with each library drive tray, to convert the connector to RJ45 connection. HP LTO 1,2,3,4 drives do not have this port. How ever HP LTO4 can be ordered with Dione card, which is an extranal interface chip, which has a native Ethernet port and this same procedure applies to that card as well.

Solution

1. The drive default IP address is 10.0.0.1 / 255.255.255.0
2. Set your laptop to that network. 10.0.0.2 for example.
3. Bring up LTO VOP client.
4. Type in the default IP and press: Connect
5. Go to: ’Configure Drive’ tab and enter in the new values.
6. Click: Set Offline
7. Click: Commit
8. Done.

See VOP pictures in the attachment.