Solution Type  Technical Instruction Sure

Solution  2103429.1 :   Measurement Report Mtcd-PATH.CSV is Not Processed By E5MS  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
  •  




In this Document
Goal
Solution
References


Created from <SR 3-12086128171>

Applies to:

Oracle Communications EAGLE (Software) - Version E5-MS 45.0 to E5-MS 46.2 [Release E5-MS 45.0 to E5-MS 46.0]
Tekelec

Goal

MTCD Reports not being processed by E5MS 45.0.1
 

Solution

The measurement related info is in common.config file
when we look into it; we see a path /Tekelec/WebNMS/conf/tekmeas.conf
This is the path where there are entries for files that should not be parsed
The two entries in this file show for MTCD per Path and MTCH Per Path.
So mtcd per path and mtch per path reports will not be parsed by the E5MS parsing process.

These files are not being processed due to fact that there are some lines in files which are not expected by code:

For a path containing CGPA only, PATH-OPCODE = <CGPA-NP-NAI-OPCODE
For a path containing both CGPA and CDPA, PATH-OPCODE = ^CGPA-NP-NAI>CDPA-NP-NAI-OPCODE”

bug 19554535 has been created for the issue that will be resolved in E5MS 46.0.1


 

References

<BUG:19554535> - MEAS PROCESSING FAILS TO PROCESS HOURLY MTCH-PATH FILES AND BLOCKS PROCESING