Solution Type
Technical Instruction Sure
Solution
2085539.1
:
SPARC M7 Series Servers : SWU FPGA firmware update
Related Categories |
- PLA-Support>Sun Systems>SPARC>Enterprise>SN-SPARC: M7
|
In this Document
Applies to:
SPARC M7-8 - Version All Versions and later
SPARC M7-16 - Version All Versions and later
Information in this document applies to any platform.
Goal
The goal of this document is to describe how to upgrade the SWU FPGA Firmware on SPARC M7 series server.
The platform should be running SysFW 9.5.2.g or later.
Note that several components of the SPARC M7 Series Servers are using FPGA. Those components must be running the latest version.
The following table provides the list of components and the respective latest versions available.
Platform Type |
Component |
FPGA Version |
M7-16, M7-8 with one or 2 Pdoms |
CMIOU |
X.3.8.3 |
M7-16, M7-8 with one or 2 Pdoms |
SP |
15.1.3.4 |
M7-16 |
SPP |
15.1.3.4 |
M7-16 |
SWU |
Y.2.0.5 |
If the platform is having several components running with downrev FPGA then all of the components should be updated. See section 4. below.
This document also contains the procedure to check the FPGA versions and how to update.
When replacing a SWU on M7-16 servers, the procedure described below must be applied to check and update the FPGA version running on the newly installed SWU.
Updating the FPGA requires to power cycle the component. A complete platform power cycle is not required. This can be done by reseating the SWU.
This document provides the methods to perform this operation.
Solution
1. How to check the FPGA versions
It's possible to check the FPGA versions from Restricted Shell on the Active SP.
Example from an M7-16 server :
-> set SESSION mode=restricted
WARNING: The "Restricted Shell" account is provided solely
to allow Services to perform diagnostic tasks.
[(restricted_shell) m7-16-sp:~]# hw version | grep "M7_FPGA" 19. /SYS/CMIOU0/FPGA (M7_FPGA) Version: 7.3.7.565. /SYS/CMIOU1/FPGA (M7_FPGA) Version: 7.3.7.5111. /SYS/CMIOU4/FPGA (M7_FPGA) Version: 7.3.7.5157. /SYS/CMIOU5/FPGA (M7_FPGA) Version: 7.3.7.5203. /SYS/CMIOU8/FPGA (M7_FPGA) Version: 7.3.7.5249. /SYS/CMIOU9/FPGA (M7_FPGA) Version: 7.3.7.5295. /SYS/CMIOU12/FPGA (M7_FPGA) Version: 7.3.7.5341. /SYS/CMIOU13/FPGA (M7_FPGA) Version: 7.3.7.5401. /SYS/SP0/FPGA (M7_FPGA) Version: 15.1.2.11412. /SYS/SP1/FPGA (M7_FPGA) Version: 15.1.2.11423. /SYS/SPP0/FPGA (M7_FPGA) Version: 15.1.2.11435. /SYS/SPP1/FPGA (M7_FPGA) Version: 15.1.2.11447. /SYS/SPP2/FPGA (M7_FPGA) Version: 15.1.2.11459. /SYS/SPP3/FPGA (M7_FPGA) Version: 15.1.2.11477. /SYS/SWU0/FPGA (M7_FPGA) Version: 6.2.0.2502. /SYS/SWU1/FPGA (M7_FPGA) Version: 6.2.0.2527. /SYS/SWU2/FPGA (M7_FPGA) Version: 6.2.0.2552. /SYS/SWU3/FPGA (M7_FPGA) Version: 6.2.0.2577. /SYS/SWU4/FPGA (M7_FPGA) Version: 6.2.0.2602. /SYS/SWU5/FPGA (M7_FPGA) Version: 6.2.0.2
Note : You can safely ignore any "idtxx_version call failed version=" messages.
Note that this information is also collected by ILOM Snapshot; in the ilom/@usr@local@bin@hw_version_-local.out file.
Example from an M7-8 server
-bash-4.1$ grep "/FPGA" ilom/@usr@local@bin@hw_version_-local.out
19. /SYS/CMIOU0/FPGA (M7_FPGA) Version: 7.3.7.5
65. /SYS/CMIOU1/FPGA (M7_FPGA) Version: 7.3.7.5
111. /SYS/CMIOU2/FPGA (M7_FPGA) Version: 7.3.7.5
157. /SYS/CMIOU3/FPGA (M7_FPGA) Version: 7.3.7.5
184. /SYS/SP0/FPGA (M7_FPGA) Version: 15.1.2.11
Example from an M7-16 server
-bash-4.1$ grep "/FPGA" ilom/*hw*
9. /SYS/SP0/FPGA (M7_FPGA) Version: 15.1.2.11
26. /SYS/SWU0/FPGA (M7_FPGA) Version: 6.2.0.2
51. /SYS/SWU1/FPGA (M7_FPGA) Version: 6.2.0.2
76. /SYS/SWU2/FPGA (M7_FPGA) Version: 6.2.0.2
101. /SYS/SWU3/FPGA (M7_FPGA) Version: 6.2.0.2
126. /SYS/SWU4/FPGA (M7_FPGA) Version: 6.2.0.2
151. /SYS/SWU5/FPGA (M7_FPGA) Version: 6.2.0.2
-bash-4.1$ grep "/FPGA" spp_snapshot/*/ilom/*hw*
spp_snapshot/SPP0@SPM0/ilom/@usr@local@bin@hw_version_-local.out:19. /SYS/CMIOU0/FPGA (M7_FPGA) Version: 7.3.7.5
spp_snapshot/SPP0@SPM0/ilom/@usr@local@bin@hw_version_-local.out:65. /SYS/CMIOU1/FPGA (M7_FPGA) Version: 7.3.7.5
spp_snapshot/SPP0@SPM0/ilom/@usr@local@bin@hw_version_-local.out:105. /SYS/SPP0/FPGA (M7_FPGA) Version: 15.1.2.11
spp_snapshot/SPP1@SPM0/ilom/@usr@local@bin@hw_version_-local.out: 1. /SYS/SPP1/FPGA (M7_FPGA) Version: 15.1.2.11
spp_snapshot/SPP1@SPM1/ilom/@usr@local@bin@hw_version_-local.out:19. /SYS/CMIOU4/FPGA (M7_FPGA) Version: 7.3.7.5
spp_snapshot/SPP1@SPM1/ilom/@usr@local@bin@hw_version_-local.out:65. /SYS/CMIOU5/FPGA (M7_FPGA) Version: 7.3.7.5
spp_snapshot/SPP2@SPM0/ilom/@usr@local@bin@hw_version_-local.out:19. /SYS/CMIOU8/FPGA (M7_FPGA) Version: 7.3.7.5
spp_snapshot/SPP2@SPM0/ilom/@usr@local@bin@hw_version_-local.out:65. /SYS/CMIOU9/FPGA (M7_FPGA) Version: 7.3.7.5
spp_snapshot/SPP2@SPM0/ilom/@usr@local@bin@hw_version_-local.out:105. /SYS/SPP2/FPGA (M7_FPGA) Version: 15.1.2.11
spp_snapshot/SPP3@SPM0/ilom/@usr@local@bin@hw_version_-local.out: 1. /SYS/SPP3/FPGA (M7_FPGA) Version: 15.1.2.11
spp_snapshot/SPP3@SPM1/ilom/@usr@local@bin@hw_version_-local.out:19. /SYS/CMIOU12/FPGA (M7_FPGA) Version: 7.3.7.5
spp_snapshot/SPP3@SPM1/ilom/@usr@local@bin@hw_version_-local.out:65. /SYS/CMIOU13/FPGA (M7_FPGA) Version: 7.3.7.5
If several components are reporting downrev FPGA version compared to the following table then refer to the procedure available in point 4. below.
Platform Type |
Component |
FPGA Version |
M7-16, M7-8 with one or 2 Pdoms |
CMIOU |
X.3.8.3 |
M7-16, M7-8 with one or 2 Pdoms |
SP |
15.1.3.4 |
M7-16 |
SPP |
15.1.3.4 |
M7-16 |
SWU |
Y.2.0.5 |
In the context of a SWU replacement, please refer to the procedure described in point 3. below.
2. Obtain the firmware image from MOS
Log to My Oracle Support, from the Patches and Updates tab, "Patch Search" select "Product or Family (Advanced)".
Select the Product as SPARC M7-8 or M7-16 and from the Release list, select with SPARC M7-8 or SPARC M7-16 HW Programmables 1.0.6.a.
Click Search and download the appropriate image.
HWP
|
Patch |
FW revision |
README File |
1.0.6.a |
26970558 |
X.3.8.3 / 15.1.3.4 / Y.2.0.5 |
README |
Always refer to the associated README file for any specific instruction.
The downloaded zip file contains the .pkg file : Hardware_Programmables-1.0.6.a-SPARC_M7-Systems.pkg
This single .pkg file contains the FPGA images for all of the components (CMIOU, SWU and SP/SPP).
Place the firmware image on a server supporting one of the following protocols:
TFTP, FTP, SFTP, SCP, HTTP, or HTTPS.
3. Update SWU FPGA upon SWU replacement
When replacing a SWU in an M7-16 server, the new SWU is more likely running a downrev FPGA.
Replacing a SWU requires all of the physical domains to be off (stop /System).
3.1 SWU replacement
The SWU replacement procedure is described in M7-16 How to replace a Faulty Switch Unit in a Switch Chassis (Doc ID 1987712.1).
Please follow the procedure to physically replace the SWU.
After installing the new SWU, you will see the following message in the event logs :
-> show /SP/logs/event/list/
Event
ID Date/Time Class Type Severity
----- ------------------------ -------- -------- --------
1278 Tue Dec 15 16:25:27 2015 Chassis Log major
/SYS/SWU0/FPGA update required.
1277 Tue Dec 15 16:25:16 2015 Chassis Action major
Hot insertion of /SYS/SWU0
The message basically confirms that an FPGA upgrade is required. You should proceed with the FPGA update.
3.2 FPGA update
To update the SWU FPGA, please follow the following procedure.
While the hosts are still off and the new SWU has been inserted, from the Active SP, apply the downloaded FPGA image by running
The load command supports the following protocols : TFTP, FTP, SFTP, SCP, HTTP, or HTTPS.
The SWU FPGA update will take up to 15 minutes to complete. But the whole process will take more time to complete.
Do NOT power cycle any components until this script is reporting success.
Example :
-> load -source scp://sdutille@lab-apps/home/sdutille/Hardware_Programmables-1.0.6.a-SPARC_M7-Systems.pkg
Enter remote user password: *********
NOTE: An upgrade takes several minutes to complete. ILOM
will enter a special mode to load new firmware. No
other tasks can be performed in ILOM until the
firmware upgrade is complete and ILOM is reset.
NOTE: HOST0 is powered on; HOST0 firmware will be updated
automatically when HOST0 is restarted.
NOTE: HOST3 is powered on; HOST3 firmware will be updated
automatically when HOST3 is restarted.
Are you sure you want to load the specified file (y/n)? y
2015-12-15 17:16:36 Install firmware package...
Version: 100.1.0.6
Finish update of: FPGA Update v1.0.6 for M7.
************************************************************
WARNING: the script can take a very long time to finish.
(Up to 15 minutes per SP, SPP, CMIOU, and SWU board)
DO NOT INTERRUPT the script, it may result in a dead board.
************************************************************
2015-12-15 17:18:38 Found /SYS/SP0/SPM0, Active
2015-12-15 17:18:41 Found /SYS/SP1/SPM0, Standby
2015-12-15 17:18:43 Found /SYS/SPP0/SPM0, Proxy Golden
2015-12-15 17:18:45 Found /SYS/SPP0/SPM1, Proxy Inactive
2015-12-15 17:18:47 Found /SYS/SPP1/SPM0, Proxy Inactive
2015-12-15 17:18:49 Found /SYS/SPP1/SPM1, Proxy Golden
2015-12-15 17:18:52 Found /SYS/SPP2/SPM0, Proxy Golden
2015-12-15 17:18:55 Found /SYS/SPP2/SPM1, Proxy Golden
2015-12-15 17:18:57 Found /SYS/SPP3/SPM0, Proxy Inactive
2015-12-15 17:18:59 Found /SYS/SPP3/SPM1, Proxy Inactive
2015-12-15 17:19:48 Copying script to the SPMs...
2015-12-15 17:19:54 Copying FPGA image to the SPMs...
2015-12-15 17:22:59 Running FPGA update on /SYS/SPP2/SPM1
2015-12-15 17:22:59 Running FPGA update on /SYS/SPP2/SPM0
2015-12-15 17:22:59 Running FPGA update on /SYS/SPP3/SPM0
2015-12-15 17:22:59 Running FPGA update on /SYS/SP1/SPM0
2015-12-15 17:22:59 Running FPGA update on /SYS/SPP0/SPM0
2015-12-15 17:22:59 Running FPGA update on /SYS/SPP1/SPM0
2015-12-15 17:23:00 Running FPGA update on /SYS/SPP1/SPM1
2015-12-15 17:23:00 Running FPGA update on /SYS/SP0/SPM0
.............................................................................................................................................................
2015-12-15 17:41:14 /SYS/SP0/SPM0 : SWU0 FPGA update success
2015-12-15 17:41:14 /SYS/SP0/SPM0 : SP FPGA verify success
2015-12-15 17:41:14 /SYS/SP0/SPM0 : SWU1 FPGA verify success
2015-12-15 17:41:14 /SYS/SP0/SPM0 : SWU2 FPGA verify success
2015-12-15 17:41:14 /SYS/SP0/SPM0 : SWU3 FPGA verify success
2015-12-15 17:41:15 /SYS/SP0/SPM0 : SWU4 FPGA verify success
2015-12-15 17:41:15 /SYS/SP0/SPM0 : SWU5 FPGA verify success
2015-12-15 17:41:15 /SYS/SP1/SPM0 : SP FPGA verify success
2015-12-15 17:41:15 /SYS/SPP0/SPM0 : CMIOU0 FPGA verify success
2015-12-15 17:41:15 /SYS/SPP0/SPM0 : CMIOU1 FPGA verify success
2015-12-15 17:41:15 /SYS/SPP0/SPM0 : SP FPGA verify success
2015-12-15 17:41:16 /SYS/SPP1/SPM0 : SP FPGA verify success
2015-12-15 17:41:16 /SYS/SPP1/SPM1 : CMIOU4 FPGA verify success
2015-12-15 17:41:16 /SYS/SPP1/SPM1 : CMIOU5 FPGA verify success
2015-12-15 17:41:16 /SYS/SPP2/SPM0 : CMIOU8 FPGA verify success
2015-12-15 17:41:16 /SYS/SPP2/SPM0 : CMIOU9 FPGA verify success
2015-12-15 17:41:16 /SYS/SPP2/SPM0 : SP FPGA verify success
2015-12-15 17:41:17 /SYS/SPP2/SPM1 : CMIOU12 FPGA verify success
2015-12-15 17:41:17 /SYS/SPP2/SPM1 : CMIOU13 FPGA verify success
2015-12-15 17:41:17 /SYS/SPP3/SPM0 : SP FPGA verify success
2015-12-15 17:41:17 FPGAs are at the latest revision.
2015-12-15 17:41:17 All done.
Finished updates
Firmware update is complete.
2015-12-15 17:41:25 Completed install
Note : If the command reports a failure, re-run the command. If the command fails again, contact Service and the owner of the SR.
At this point, the FPGA image has not yet been applied. A SWU power cycle is required. This can be done by unseating and reseating the SWU.
This may imply to stop the hosts if necessary. And to return the replaced SWU to the configuration, all of the hosts will have to be restarted.
So, it may be easier to go for a complete platform power cycle. See point the note below.
As described below :
- Prepare the SWU for removal.
-> set /System/Other_Removable_Devices/Scalability_Switch_Boards/Scalability_Switch_Board_x action=prepare_to_remove
- Verify that the SWU is ready to be removed.
-> show /System/Other_Removable_Devices/Scalability_Switch_Boards/Scalability_Switch_Board_x health
This should return the SWU as "Offline".
- Verify that the blue Ready to Remove light on the SWU is on.
- Unseat the SWU
- Pull the ejector arms out to disengage the switch unit from the server.
- Press the arms back toward the unit to prevent them from being damaged.
- Pull the switch unit out of the server less than halfway.
- Wait 30 seconds
- Reseat the SWU
- Slide the switch unit back into the server until the levers begin to engage.
- Press the arms back toward the switch unit, and then press the arms firmly against the switch unit to fully seat the switch back into the server.
This procedure is also documented in the SPARC M7 Series Servers Service Manual.
Note : In order to power cycle the component, after replacing the SWU, instead of unseating/reseating the SWU, it's also possible to power cycle the platform (by switching off/on the respective breakers on the rack). PDU breakers switch on/off sequences are described in the Service Manual:
Of course, this will extend the maintenance window as the SP and/or SPP will reset.
Check from Restricted Shell that the SWU is now running the latest version
[(restricted_shell) m7-16-sp:~]# hw version | grep SWU | grep "/FPGA"
And confirm from the above output that all of the SWUs are running the same FPGA version.
At this stage, the replaced component has been updated, the hosts can be restarted (start /System).
3.3 No update required
When running the command, if no update is required, the command will just return as following :
-> load -source scp://sdutille@lab-apps/home/sdutille/Hardware_Programmables-1.0.6.a-SPARC_M7-Systems.pkg
Enter remote user password: *********
NOTE: An upgrade takes several minutes to complete. ILOM
will enter a special mode to load new firmware. No
other tasks can be performed in ILOM until the
firmware upgrade is complete and ILOM is reset.
Are you sure you want to load the specified file (y/n)? y
2015-12-15 17:16:36 Install firmware package...
Version: 100.1.0.6
Finish update of: FPGA Update v1.0.6 for M7.
************************************************************
WARNING: the script can take a very long time to finish.
(Up to 15 minutes per SP, SPP, CMIOU, and SWU board)
DO NOT INTERRUPT the script, it may result in a dead board.
************************************************************
2015-12-15 17:18:38 Found /SYS/SP0/SPM0, Active
2015-12-15 17:18:41 Found /SYS/SP1/SPM0, Standby
2015-12-15 17:18:43 Found /SYS/SPP0/SPM0, Proxy Golden
2015-12-15 17:18:45 Found /SYS/SPP0/SPM1, Proxy Inactive
2015-12-15 17:18:47 Found /SYS/SPP1/SPM0, Proxy Inactive
2015-12-15 17:18:49 Found /SYS/SPP1/SPM1, Proxy Golden
2015-12-15 17:18:52 Found /SYS/SPP2/SPM0, Proxy Golden
2015-12-15 17:18:55 Found /SYS/SPP2/SPM1, Proxy Golden
2015-12-15 17:18:57 Found /SYS/SPP3/SPM0, Proxy Inactive
2015-12-15 17:18:59 Found /SYS/SPP3/SPM1, Proxy Inactive
2015-12-15 17:19:48 Copying script to the SPMs...
2015-12-15 17:19:54 Copying FPGA image to the SPMs...
2015-12-15 17:22:59 Running FPGA update on /SYS/SPP2/SPM1
2015-12-15 17:22:59 Running FPGA update on /SYS/SPP2/SPM0
2015-12-15 17:22:59 Running FPGA update on /SYS/SPP3/SPM0
2015-12-15 17:22:59 Running FPGA update on /SYS/SP1/SPM0
2015-12-15 17:22:59 Running FPGA update on /SYS/SPP0/SPM0
2015-12-15 17:22:59 Running FPGA update on /SYS/SPP1/SPM0
2015-12-15 17:23:00 Running FPGA update on /SYS/SPP1/SPM1
2015-12-15 17:23:00 Running FPGA update on /SYS/SP0/SPM0
.........................................................................................................................................................................
2015-12-15 17:41:14 /SYS/SP0/SPM0 : SWU0 FPGA verify success
2015-12-15 17:41:14 /SYS/SP0/SPM0 : SP FPGA verify success
2015-12-15 17:41:14 /SYS/SP0/SPM0 : SWU1 FPGA verify success
2015-12-15 17:41:14 /SYS/SP0/SPM0 : SWU2 FPGA verify success
2015-12-15 17:41:14 /SYS/SP0/SPM0 : SWU3 FPGA verify success
2015-12-15 17:41:15 /SYS/SP0/SPM0 : SWU4 FPGA verify success
2015-12-15 17:41:15 /SYS/SP0/SPM0 : SWU5 FPGA verify success
2015-12-15 17:41:15 /SYS/SP1/SPM0 : SP FPGA verify success
2015-12-15 17:41:15 /SYS/SPP0/SPM0 : CMIOU0 FPGA verify success
2015-12-15 17:41:15 /SYS/SPP0/SPM0 : CMIOU1 FPGA verify success
2015-12-15 17:41:15 /SYS/SPP0/SPM0 : SP FPGA verify success
2015-12-15 17:41:16 /SYS/SPP1/SPM0 : SP FPGA verify success
2015-12-15 17:41:16 /SYS/SPP1/SPM1 : CMIOU4 FPGA verify success
2015-12-15 17:41:16 /SYS/SPP1/SPM1 : CMIOU5 FPGA verify success
2015-12-15 17:41:16 /SYS/SPP2/SPM0 : CMIOU8 FPGA verify success
2015-12-15 17:41:16 /SYS/SPP2/SPM0 : CMIOU9 FPGA verify success
2015-12-15 17:41:16 /SYS/SPP2/SPM0 : SP FPGA verify success
2015-12-15 17:41:17 /SYS/SPP2/SPM1 : CMIOU12 FPGA verify success
2015-12-15 17:41:17 /SYS/SPP2/SPM1 : CMIOU13 FPGA verify success
2015-12-15 17:41:17 /SYS/SPP3/SPM0 : SP FPGA verify success
2015-12-15 17:41:17 FPGAs are at the latest revision.
2015-12-15 17:41:17 All done.
Finished updates
Firmware update is complete.
2015-12-15 17:41:25 Completed install
4. Update FPGA for more than one component
If more than one component require FPGA update, the preferred method is probably to :
- Stop all of the running hosts
- From the Active SP, apply the downloaded FPGA image by running
The load command supports the following protocols : TFTP, FTP, SFTP, SCP, HTTP, or HTTPS.
The update will take up to 15 minutes per SP, SPP, CMIOU, and SWU board. But the whole process will take more time to complete.
Do NOT power cycle any components until this script is reporting success
Example :
-> load -source sftp://user@hostname//tmp/p22345376_106/Firmware/Hardware_Programmables/Hardware_Programmables-1.0.6.a-SPARC_M7-Systems.pkg
Enter remote user password: *********
NOTE: An upgrade takes several minutes to complete. ILOM
will enter a special mode to load new firmware. No
other tasks can be performed in ILOM until the
firmware upgrade is complete and ILOM is reset.
Are you sure you want to load the specified file (y/n)? y
2015-12-15 08:38:44 Install firmware package...
Version: 100.1.0.6
Finish update of: FPGA Update v1.0.6 for M7.
************************************************************
WARNING: the script can take a very long time to finish.
(Up to 15 minutes per SP, SPP, CMIOU, and SWU board)
DO NOT INTERRUPT the script, it may result in a dead board.
************************************************************
2015-12-15 09:02:05 Found /SYS/SP0/SPM0, Active
2015-12-15 09:02:07 Found /SYS/SP1/SPM0, Standby
2015-12-15 09:02:09 Found /SYS/SPP0/SPM0, Proxy Golden
2015-12-15 09:02:11 Found /SYS/SPP0/SPM1, Proxy Inactive
2015-12-15 09:02:13 Found /SYS/SPP1/SPM0, Proxy Inactive
2015-12-15 09:02:14 Found /SYS/SPP1/SPM1, Proxy Golden
2015-12-15 09:02:16 Found /SYS/SPP2/SPM0, Proxy Golden
2015-12-15 09:02:18 Found /SYS/SPP2/SPM1, Proxy Golden
2015-12-15 09:02:55 Copying script to the SPMs...
2015-12-15 09:03:00 Copying FPGA image to the SPMs...
2015-12-15 09:05:38 Running FPGA update on /SYS/SPP2/SPM1
2015-12-15 09:05:39 Running FPGA update on /SYS/SPP2/SPM0
2015-12-15 09:05:39 Running FPGA update on /SYS/SP1/SPM0
2015-12-15 09:05:39 Running FPGA update on /SYS/SPP0/SPM0
2015-12-15 09:05:39 Running FPGA update on /SYS/SPP1/SPM0
2015-12-15 09:05:39 Running FPGA update on /SYS/SPP1/SPM1
2015-12-15 09:05:39 Running FPGA update on /SYS/SP0/SPM0
..................................................................................................................................................................................................................................................................................................................................................................................................................................................................
2015-12-15 09:43:16 /SYS/SP0/SPM0 : SWU1 FPGA update success
2015-12-15 09:43:16 /SYS/SP0/SPM0 : SWU2 FPGA update success
2015-12-15 09:43:16 /SYS/SP0/SPM0 : SWU3 FPGA update success
2015-12-15 09:43:16 /SYS/SP0/SPM0 : SWU4 FPGA update success
2015-12-15 09:43:16 /SYS/SP0/SPM0 : SWU5 FPGA update success
2015-12-15 09:43:16 /SYS/SP0/SPM0 : SP FPGA update success
2015-12-15 09:43:16 /SYS/SP1/SPM0 : SP FPGA update success
2015-12-15 09:43:16 /SYS/SPP0/SPM0 : CMIOU0 FPGA update success
2015-12-15 09:43:16 /SYS/SPP0/SPM0 : CMIOU1 FPGA update success
2015-12-15 09:43:16 /SYS/SPP0/SPM0 : SP FPGA update success
2015-12-15 09:43:17 /SYS/SPP1/SPM0 : SP FPGA update success
2015-12-15 09:43:17 /SYS/SPP1/SPM1 : CMIOU4 FPGA update success
2015-12-15 09:43:17 /SYS/SPP1/SPM1 : CMIOU5 FPGA update success
2015-12-15 09:43:17 /SYS/SPP2/SPM0 : CMIOU8 FPGA update success
2015-12-15 09:43:17 /SYS/SPP2/SPM0 : CMIOU9 FPGA update success
2015-12-15 09:43:17 /SYS/SPP2/SPM0 : SP FPGA update success
2015-12-15 09:43:18 /SYS/SPP2/SPM1 : CMIOU12 FPGA update success
2015-12-15 09:43:18 /SYS/SPP2/SPM1 : CMIOU13 FPGA update success
2015-12-15 09:43:18 FPGAs are at the latest revision.
2015-12-15 09:43:18 All done.
Finished updates
Firmware update is complete.
2015-12-15 09:43:27 Completed install
Note : If the command reports a failure, re-run the command. If the command fails again, contact Service and the owner of the SR.
At this point, the FPGA image has not yet been applied. A power cycle is required.
[(restricted_shell) sp0:~]# hw version | grep "M7_FPGA"
19. /SYS/CMIOU0/FPGA (M7_FPGA) Version: 7.3.7.5
65. /SYS/CMIOU1/FPGA (M7_FPGA) Version: 7.3.7.5
111. /SYS/CMIOU4/FPGA (M7_FPGA) Version: 7.3.7.5
157. /SYS/CMIOU5/FPGA (M7_FPGA) Version: 7.3.7.5
203. /SYS/CMIOU8/FPGA (M7_FPGA) Version: 7.3.7.5
249. /SYS/CMIOU9/FPGA (M7_FPGA) Version: 7.3.7.5
295. /SYS/CMIOU12/FPGA (M7_FPGA) Version: 7.3.7.5
341. /SYS/CMIOU13/FPGA (M7_FPGA) Version: 7.3.7.5
401. /SYS/SP0/FPGA (M7_FPGA) Version: 15.1.2.11
412. /SYS/SP1/FPGA (M7_FPGA) Version: 15.1.2.11
423. /SYS/SPP0/FPGA (M7_FPGA) Version: 15.1.2.11
435. /SYS/SPP1/FPGA (M7_FPGA) Version: 15.1.2.11
447. /SYS/SPP2/FPGA (M7_FPGA) Version: 15.1.2.11
465. /SYS/SWU1/FPGA (M7_FPGA) Version: 6.2.0.2
490. /SYS/SWU2/FPGA (M7_FPGA) Version: 6.2.0.2
515. /SYS/SWU3/FPGA (M7_FPGA) Version: 6.2.0.2
540. /SYS/SWU4/FPGA (M7_FPGA) Version: 6.2.0.2
565. /SYS/SWU5/FPGA (M7_FPGA) Version: 6.2.0.2
- Power cycle the platform (by switching off/on the respective breakers on the rack). PDU breakers switch on/off sequences are described in the Service Manual:
-
When all of the SP/SPP are back online, check from Restricted Shell on the Active SP that the components is now running the latest version
[(restricted_shell) m7-16-sp:~]# hw version | grep "/FPGA"
And confirm from the above output that all of the components are running the latest FPGA versions.
- The hosts can now be restarted
-> start /System
Are you sure you want to start all of the configured hosts on the system (y/n)? y