Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-71-2081179.1
Update Date:2018-05-10
Keywords:

Solution Type  Technical Instruction Sure

Solution  2081179.1 :   Oracle ZFS Storage Appliance : How to Configure Cluster Cabling Correctly  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS5-2
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Oracle ZFS Storage ZS5-4
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Oracle ZFS Storage Appliance Racked System ZS4-4
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: 7xxx NAS
  •  




In this Document
Goal
Solution
 Sun Storage 7310 Unified Storage System
 Sun Storage 7410 Unified Storage System
 Sun ZFS Storage 7320
 Sun ZFS Storage 7420
 Sun ZFS Backup Appliance
 Oracle ZFS Storage ZS3-2
 Oracle ZFS Storage ZS3-4
 Oracle ZFS Storage ZS3-BA
 Oracle ZFS Storage ZS3-ES
 Oracle ZFS Storage ZS4-4
 Oracle ZFS Storage Appliance Racked System ZS4-4
 Oracle ZFS Storage ZS5-2
 Oracle ZFS Storage ZS5-4


Applies to:

Oracle ZFS Storage ZS3-BA - Version All Versions and later
Oracle ZFS Storage ZS4-4 - Version All Versions and later
Sun Storage 7310 Unified Storage System - Version All Versions and later
Oracle ZFS Storage Appliance Racked System ZS4-4 - Version All Versions and later
Sun Storage 7410 Unified Storage System - Version All Versions and later
7000 Appliance OS (Fishworks)

Goal

This document provides guidance (and illustrations) on how to correctly cable the cluster links between the two heads.

 

Solution

IMPORTANT NOTICE

If the 'UART0' and 'UART1' ports are cabled 'straight through' instead of 'crossover' (see the RED and BLUE cables below) there is a risk of a cluster 'split brain' situation - each cluster head believes that it is
the only 'active' head in the cluster - which could result in BOTH cluster heads importing the data pools (a 'double import').

In this situation, both cluster heads may direct I/O to the pools - which may result in data corruption.

This 'split brain' situation may occur at any time after a period of 'normal' running, and the loss of redundancy is not a 'stop' condition for the clustered appliance.

Please take extra care when performing hardware maintenance operations on one of the heads - it is critical to ensure that the clustron cables are plugged in correctly - according to the specific schema below.

 

What cables are required ?    For further information see  http://docs.oracle.com/cd/E71909_01/html/E71918/gqucg.html#scrolltoc

NOTE: "Gather the three 1-meter Ethernet cables that were supplied for connecting clustered controllers.  If supplying your own Ethernet cables, ensure they are straight-through and Category 5 or better."

 

 

Sun Storage 7310 Unified Storage System

System Part Number Clustron Card Slot
7310 371-3024 Slot 0
7310 (SAS-2) 371-3024 Slot 0
  542-0298  
  7056175  
  7089470  

 7310 cluster links

 

 

 

 

NOTE: The cables connecting the 'left' and 'right' ports CROSS OVER.

 


Sun Storage 7410 Unified Storage System

System Part Number Clustron Card Slot
7410 371-3024 Slot 5
7410 (SAS-2) 371-3024 Slot 5
  542-0298  
  7056175  
  7089470  

 7410 cluster links

 

 

 

 

NOTE: The cables connecting the 'left' and 'right' ports CROSS OVER.

 


Sun ZFS Storage 7320

System Part Number Clustron card Slot
7320 542-0298 Slot 1
  7056175  
  7089470  

 7320 cluster links

 

 

NOTE: The cables connecting the 'left' and 'right' ports CROSS OVER.

 


Sun ZFS Storage 7420

System Part Number Clustron card Slot
7420 542-0298 (Dedicated)
  7056175  
  7089470  

 7420 cluster links

 

 

NOTE: The cables connecting the 'top' and 'bottom' ports CROSS OVER.

 


Sun ZFS Backup Appliance

System Part Number Clustron card Slot
ZFS-BA 542-0298 (Dedicated)
  7056175  
  7089470  

 7420 cluster links

 

 

NOTE: The cables connecting the 'top' and 'bottom' ports CROSS OVER.

 


Oracle ZFS Storage ZS3-2

System Part Number Clustron Card Slot
ZS3-2 (On-board MB) N/A

ZS3-2 cluster links

 

NOTE: The cables connecting the 'left' and 'centre' ports CROSS OVER.

 


Oracle ZFS Storage ZS3-4

System Part Number Clustron Card Slot
ZS3-4 7056175 (Dedicated)
  7089470  

7420 cluster links

 

 

NOTE: The cables connecting the 'top' and 'bottom' ports CROSS OVER.

 


Oracle ZFS Storage ZS3-BA

System Part Number Clustron Card Slot
ZS3-BA 7056175 (Dedicated)
  7089470  

7420 cluster links

 

 

NOTE: The cables connecting the 'top' and 'bottom' ports CROSS OVER.

 


Oracle ZFS Storage ZS3-ES

System Part Number Clustron Card Slot
ZS3-ES 7056175 Slot 2
  7089470  

ZS3-ES cluster links

 

 

NOTE: The cables connecting the 'left' and 'right' ports CROSS OVER.

 


Oracle ZFS Storage ZS4-4

System Part Number Clustron Card Slot
ZS4-4 7056175 (Dedicated)
  7089470  

 7420 cluster links

 

 

NOTE: The cables connecting the 'top' and 'bottom' ports CROSS OVER.

 


Oracle ZFS Storage Appliance Racked System ZS4-4

System Part Number Clustron Card Slot
ZS4-4 Racked
7089470 (Dedicated)

7420 cluster links

 

NOTE: The cables connecting the 'top' and 'bottom' ports CROSS OVER.

 


Oracle ZFS Storage ZS5-2

System Part Number Clustron Card Slot
ZS5-2
7092289 Slot 4

7420 cluster links

 

NOTE: The cables connecting the 'top' and 'bottom' ports CROSS OVER.

 


Oracle ZFS Storage ZS5-4

System Part Number Clustron Card Slot
ZS5-4
7311641 Slot 4

7420 cluster links

 

NOTE: The cables connecting the 'top' and 'bottom' ports CROSS OVER.

 


 

 

 