Asset ID: |
1-71-2075220.1 |
Update Date: | 2018-03-01 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2075220.1
:
How to replace the Fan Tray in Cisco switch 4948
Related Items |
- Exadata X6-2 Hardware
- Big Data Appliance X6-2 Hardware
- Exadata X5-2 Eighth Rack
- Exadata X3-8 Hardware
- Exadata X4-2 Hardware
- Exadata X5-2 Hardware
- Cisco Catalyst 4948 Switch
- Oracle SuperCluster M7 Hardware
- Big Data Appliance X5-2 Hardware
- Zero Data Loss Recovery Appliance X6 Hardware
- Exadata X6-8 Hardware
- Oracle Exalogic Elastic Cloud X2-2 Hardware
- Big Data Appliance X3-2 Hardware
- Big Data Appliance X4-2 Hardware
- Exadata Database Machine X2-2 Hardware
- Exadata X4-8 Hardware
- Exadata Database Machine X2-8
- Exadata X3-2 Hardware
|
Related Categories |
- PLA-Support>Sun Systems>Sun_Other>Sun Collections>SN-OTH: SaND-CAP VCAP
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Cisco 4948 switches that are sold with Engineered Systems do not contain any CRU components
Applies to:
Zero Data Loss Recovery Appliance X6 Hardware - Version All Versions to All Versions [Release All Releases]
Oracle Exalogic Elastic Cloud X2-2 Hardware - Version X2 to X2 [Release X2]
Exadata X5-2 Hardware - Version All Versions and later
Cisco Catalyst 4948 Switch - Version All Versions and later
Exadata X6-2 Hardware - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Goal
Replacing the Fan Tray on a 4948 where there is a Fault condition such as Environmental Alarm displayed in the
Cisco#show environment output.
Solution
Removing and Installing the Fan Tray
This section describes how to remove and install the system fan tray in the Catalyst 4948E switch chassis and
contains these subsections:
Required Tools:
You might need a flat-blade or Number 2 Phillips screwdriver to loosen or tighten the captive installation screw on the fan tray.
Note: You have 30 seconds to install the replacement fan tray before the system automatically shuts down.
Removing the Fan Tray
The system fan tray can be removed and replaced while the system is operating without presenting an electrical
hazard to the user or damage to the system. A 30-second window is provided for you to remove the defective fan
tray and install the replacement tray. If you exceed 30 seconds, the system starts to overheat and automatically
shuts down.
Warning: When removing the fan tray, keep your hands and fingers away from the spinning fan blades. Let the fan blades
completely stop before you remove the fan tray.
To remove the installed fan assembly, follow these steps:
Step 1: Remove the replacement fan tray from its shipping packaging and place it near the chassis that you are working on.
Step 2: Loosen the two captive installation screws on the installed fan tray.
Step 3: Grasp the fan assembly handle, and pull it outward; gently move the fan tray from side to side, if necessary, to
unseat the fan tray power connector from the chassis connector.
Step 4: Place your free hand under the fan tray to support it. Pull the fan assembly clear of the chassis, and set it aside.
Installing the Fan Tray
To install the new fan tray, follow these steps:
Step 1: Position the replacement fan tray in front of the fan tray bay at the rear of the chassis.
Step 2: Slide the fan tray into the fan tray bay until the power connector seats in the chassis fan connector and the
captive installation screws make contact with the chassis. The fans should immediately power up.
Step 3: Tighten the two fan tray captive installation screws to secure the fan tray in the chassis.
Step 4: Verify that the FAN LED on the chassis front panel is lit green
References
<NOTE:1922959.1> - One Of The Power Supplies On The Cisco (admin) Switch Shows Two Red Lights And Needs Repair
Attachments
This solution has no attachment