Asset ID: |
1-71-2069817.1 |
Update Date: | 2017-01-04 |
Keywords: | |
Solution Type
Technical Instruction Sure
Solution
2069817.1
:
Low xDR Correlation in RAN CC2 Sessions
Related Items |
- Oracle Communications Performance Intelligence Center (PIC) Software
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec PIC
|
In this Document
Created from <SR 3-10231122701>
Applies to:
Oracle Communications Performance Intelligence Center (PIC) Software - Version 10.1.0 to 10.1.5 [Release 10.0]
Information in this document applies to any platform.
Goal
Correlation rate is low on session based on RAN CC2 dictionary. Iu Release and Iu Release Complete messages are not correlated.
Solution
IuC Release/Release complete messages shouldn't normally be part of RAN CC2 session, thus correlation of this messages is not expected and xDRs related to these messages will have DR status "Not Matched". In turn, since correlation rate is calculated based on all xDRs in session, this will cause decreased correlation rates. If required, these 2 messages can be filtered out while creating a correlation success rate KPI or during manual calculation.
This issue is tracked by bug 20591578.
References
<BUG:20591578> - RAN CC2: IUC RELEASE ALONE SHOULD NOT RESULT IN XDR
Attachments
This solution has no attachment